{"id":10370,"date":"2026-02-09T13:04:47","date_gmt":"2026-02-09T11:04:47","guid":{"rendered":"https:\/\/refrigerationstore.eu\/?p=10370"},"modified":"2026-05-18T20:10:23","modified_gmt":"2026-05-18T17:10:23","slug":"guide-des-refrigerants-a-faible-prp-2026-reglementation-f-gaz-a2l-et-alternatives-naturelles","status":"publish","type":"post","link":"https:\/\/refrigerationstore.eu\/fr\/gas\/guide-des-refrigerants-a-faible-prp-2026-reglementation-f-gaz-a2l-et-alternatives-naturelles\/","title":{"rendered":"Guide des R\u00e9frig\u00e9rants \u00e0 Faible PRP 2026 : R\u00e9glementation F-Gaz, A2L et Alternatives Naturelles"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Un \u00ab r\u00e9frig\u00e9rant \u00e0 faible PRP (GWP) \u00bb en 2026, c&rsquo;est tout fluide frigorig\u00e8ne dont le Potentiel de R\u00e9chauffement Plan\u00e9taire se situe sous le seuil fix\u00e9 par le r\u00e8glement F-Gaz (UE) 2024\/573 pour sa cat\u00e9gorie d&rsquo;\u00e9quipement. Pour les climatiseurs split et les pompes \u00e0 chaleur (PAC), l&rsquo;interdiction vise un PRP sup\u00e9rieur ou \u00e9gal \u00e0 150 d\u00e8s le 1er janvier 2027 (<a href=\"https:\/\/eur-lex.europa.eu\/legal-content\/FR\/TXT\/?uri=CELEX:32024R0573\" target=\"_blank\" rel=\"noopener nofollow\">R\u00e8glement (UE) 2024\/573, Annexe IV<\/a>). La liste des options conformes se divise en chimies tr\u00e8s diff\u00e9rentes : les m\u00e9langes A2L comme le R-32 et le R-454B pour la climatisation et les PAC, le R-290 (propane) pour les meubles frigorifiques autonomes, le R-744 (CO\u2082) pour les centrales de supermarch\u00e9s en transcritique, et le R-717 (ammoniac) pour le froid industriel et l&rsquo;entreposage. Ce guide passe en revue chaque r\u00e9frig\u00e9rant autoris\u00e9 par la r\u00e9glementation europ\u00e9enne, les cas o\u00f9 chacun s&rsquo;impose, et les normes de s\u00e9curit\u00e9 qui les encadrent.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote key-takeaways is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Points Cl\u00e9s<\/strong><\/p><ul><li>Le R-32 domine le march\u00e9 europ\u00e9en des splits et PAC avec environ 55 % des nouvelles installations en 2025, port\u00e9 par Daikin depuis 2014 et suivi par la quasi-totalit\u00e9 des constructeurs europ\u00e9ens (<a href=\"https:\/\/www.ehpa.org\/\" target=\"_blank\" rel=\"noopener nofollow\">EHPA, 2025<\/a>).<\/li><li>Le r\u00e8glement F-Gaz (UE) 2024\/573 interdit les nouveaux split AC avec un PRP \u2265 150 d\u00e8s janvier 2027 et r\u00e9duit le quota HFC \u00e0 5 % de la ligne de base d&rsquo;ici 2030.<\/li><li>La limite de charge du R-290 (propane, PRP 3) est pass\u00e9e de 150 g \u00e0 500 g sous l&rsquo;EN IEC 60335-2-89:2022, ouvrant la voie \u00e0 la majorit\u00e9 des meubles frigorifiques autonomes.<\/li><li>Plus de 50 000 syst\u00e8mes transcritiques au R-744 (CO\u2082, PRP 1) fonctionnent dans les supermarch\u00e9s europ\u00e9ens fin 2025, dont Carrefour, ALDI, Lidl et Tesco.<\/li><li>Le R-717 (ammoniac, PRP 0) assure la majorit\u00e9 du froid industriel europ\u00e9en ; il est encadr\u00e9 par l&rsquo;EN 378 et la directive Seveso III, pas par les quotas HFC.<\/li><\/ul><\/blockquote>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"quest-ce-faible-prp\">Qu&rsquo;est-ce qu&rsquo;un R\u00e9frig\u00e9rant \u00ab \u00e0 Faible PRP \u00bb en 2026 ?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le r\u00e8glement F-Gaz d\u00e9finit \u00ab faible PRP \u00bb de mani\u00e8re sectorielle : il ne s&rsquo;agit pas d&rsquo;un seuil unique mais d&rsquo;une s\u00e9rie d&rsquo;interdictions par cat\u00e9gorie d&rsquo;\u00e9quipement publi\u00e9es \u00e0 l&rsquo;Annexe IV du R\u00e8glement (UE) 2024\/573. Pour les nouveaux syst\u00e8mes split de climatisation et les PAC split, le plafond effectif tombe \u00e0 PRP 150 d\u00e8s janvier 2027. Pour les meubles frigorifiques plug-in commerciaux, le seuil de PRP 150 est d\u00e9j\u00e0 en vigueur depuis 2025. Les centrales multipack de plus de 40 kW sont limit\u00e9es \u00e0 un PRP inf\u00e9rieur \u00e0 150 depuis 2022.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"prp-explique\">Le PRP (Potentiel de R\u00e9chauffement Plan\u00e9taire), comment \u00e7a marche ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le PRP mesure la quantit\u00e9 de chaleur qu&rsquo;un r\u00e9frig\u00e9rant pi\u00e8ge dans l&rsquo;atmosph\u00e8re sur 100 ans par rapport \u00e0 une masse \u00e9gale de CO\u2082. Le R-410A affiche un PRP de 2 088 (AR4) ou 1 924 (AR5), ce qui signifie qu&rsquo;un kilogramme de R-410A rel\u00e2ch\u00e9 retient autant de chaleur que 1 924 kg de CO\u2082 (en valeur AR5). Le R-32 (PRP 675) et le R-454B (PRP 466) passent tous deux sous le seuil de 700 utilis\u00e9 aux \u00c9tats-Unis, mais seul le R-32 pur est en dessous de 150 une fois m\u00e9lang\u00e9 avec un HFO dans des solutions comme le R-454B. En pratique, le seuil europ\u00e9en de 150 pour les splits pousse l&rsquo;industrie vers le R-32 ou le R-290 pour les \u00e9quipements neufs \u00e0 partir de 2027.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"ar4-vs-ar5\">AR4 ou AR5 : quelle valeur de PRP utiliser ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Depuis le 1er janvier 2025, le r\u00e8glement F-Gaz (UE) 2024\/573 impose les valeurs AR5 du GIEC pour toute d\u00e9claration r\u00e9glementaire dans l&rsquo;Union europ\u00e9enne. Les valeurs AR4 restent la r\u00e9f\u00e9rence aux \u00c9tats-Unis (ASHRAE Standard 34). Si vous sp\u00e9cifiez des \u00e9quipements pour les deux march\u00e9s, vos fiches techniques doivent mentionner les deux valeurs. Le R-410A passe de 2 088 (AR4) \u00e0 1 924 (AR5). Le R-32 reste \u00e0 675. Le R-454B descend \u00e0 environ 460. Cela ne change pas les choix de conformit\u00e9, mais cela modifie la paperasse de reporting.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"reglementation-fgaz\">Le R\u00e8glement F-Gaz (UE) 2024\/573 en 2026<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le cadre r\u00e9glementaire europ\u00e9en repose sur deux piliers : le syst\u00e8me de quotas HFC (qui plafonne la production et l&rsquo;importation) et les interdictions sectorielles (qui restreignent la mise sur le march\u00e9 par cat\u00e9gorie d&rsquo;\u00e9quipement). Le r\u00e8glement r\u00e9vis\u00e9 (UE) 2024\/573, entr\u00e9 en vigueur le 11 mars 2024, durcit consid\u00e9rablement les deux volets par rapport \u00e0 la version pr\u00e9c\u00e9dente de 2014. Pour les professionnels du froid et de la climatisation, les dates critiques se concentrent entre 2025 et 2030.<\/p>\n\n\n\n<figure class=\"chart-figure\" style=\"margin:1.5em 0;text-align:center;\">\n<svg viewBox=\"0 0 700 370\" role=\"img\" aria-label=\"Calendrier des interdictions par secteur selon le r\u00e8glement F-Gaz (UE) 2024\/573, de 2022 \u00e0 2030\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" style=\"max-width:100%;height:auto;background:transparent;\">\n<style>.gt-ttl{font:700 14px system-ui,sans-serif;fill:currentColor;}.gt-lbl{font:600 11px system-ui,sans-serif;fill:currentColor;}.gt-cap{font:600 10px system-ui,sans-serif;fill:#fff;}.gt-yr{font:11px system-ui,sans-serif;fill:currentColor;opacity:.7;}.gt-src{font:10px system-ui,sans-serif;fill:currentColor;opacity:.65;}.gt-hd{font:700 11px system-ui,sans-serif;fill:currentColor;opacity:.7;}.gt-now{font:700 10px system-ui,sans-serif;fill:#dc2626;}<\/style>\n<text x=\"20\" y=\"24\" class=\"gt-ttl\">R\u00e8glement F-Gaz (UE) 2024\/573 : calendrier des interdictions par secteur<\/text>\n<line x1=\"200\" y1=\"55\" x2=\"200\" y2=\"310\" stroke=\"currentColor\" stroke-opacity=\".15\"\/>\n<line x1=\"310\" y1=\"55\" x2=\"310\" y2=\"310\" stroke=\"currentColor\" stroke-opacity=\".15\"\/>\n<line x1=\"420\" y1=\"55\" x2=\"420\" y2=\"310\" stroke=\"currentColor\" stroke-opacity=\".15\"\/>\n<line x1=\"530\" y1=\"55\" x2=\"530\" y2=\"310\" stroke=\"currentColor\" stroke-opacity=\".15\"\/>\n<line x1=\"640\" y1=\"55\" x2=\"640\" y2=\"310\" stroke=\"currentColor\" stroke-opacity=\".15\"\/>\n<text x=\"200\" y=\"48\" class=\"gt-yr\" text-anchor=\"middle\">2022<\/text>\n<text x=\"310\" y=\"48\" class=\"gt-yr\" text-anchor=\"middle\">2025<\/text>\n<text x=\"420\" y=\"48\" class=\"gt-yr\" text-anchor=\"middle\">2027<\/text>\n<text x=\"530\" y=\"48\" class=\"gt-yr\" text-anchor=\"middle\">2029<\/text>\n<text x=\"640\" y=\"48\" class=\"gt-yr\" text-anchor=\"middle\">2030<\/text>\n<!-- \"NOUS SOMMES ICI\" marker at ~2026 position (between 2025 and 2027) -->\n<line x1=\"365\" y1=\"42\" x2=\"365\" y2=\"310\" stroke=\"#dc2626\" stroke-width=\"2\" stroke-dasharray=\"4,3\"\/>\n<text x=\"365\" y=\"40\" class=\"gt-now\" text-anchor=\"middle\">NOUS SOMMES ICI<\/text>\n<text x=\"20\" y=\"80\" class=\"gt-hd\">Secteur<\/text>\n<text x=\"20\" y=\"105\" class=\"gt-lbl\">Centrales multipack &gt; 40 kW<\/text>\n<rect x=\"200\" y=\"93\" width=\"445\" height=\"18\" fill=\"#059669\" rx=\"2\"\/>\n<text x=\"422\" y=\"106\" class=\"gt-cap\" text-anchor=\"middle\">PRP \u2265 150 interdit depuis 2022 (en vigueur)<\/text>\n<text x=\"20\" y=\"140\" class=\"gt-lbl\">Froid commercial plug-in<\/text>\n<rect x=\"310\" y=\"128\" width=\"335\" height=\"18\" fill=\"#10b981\" rx=\"2\"\/>\n<text x=\"477\" y=\"141\" class=\"gt-cap\" text-anchor=\"middle\">PRP \u2265 150 interdit depuis janv. 2025<\/text>\n<text x=\"20\" y=\"175\" class=\"gt-lbl\">Split AC \/ PAC split<\/text>\n<rect x=\"420\" y=\"163\" width=\"225\" height=\"18\" fill=\"#0ea5e9\" rx=\"2\"\/>\n<text x=\"532\" y=\"176\" class=\"gt-cap\" text-anchor=\"middle\">PRP \u2265 150 interdit d\u00e8s janv. 2027<\/text>\n<text x=\"20\" y=\"210\" class=\"gt-lbl\">PAC monobloc charge \u2265 3 kg<\/text>\n<rect x=\"420\" y=\"198\" width=\"225\" height=\"18\" fill=\"#f59e0b\" rx=\"2\"\/>\n<text x=\"532\" y=\"211\" class=\"gt-cap\" text-anchor=\"middle\">HFC interdit d\u00e8s janv. 2027<\/text>\n<text x=\"20\" y=\"245\" class=\"gt-lbl\">Quota HFC (% ligne de base)<\/text>\n<rect x=\"200\" y=\"233\" width=\"110\" height=\"18\" fill=\"#6366f1\" rx=\"2\"\/>\n<text x=\"255\" y=\"246\" class=\"gt-cap\" text-anchor=\"middle\">31 %<\/text>\n<rect x=\"420\" y=\"233\" width=\"110\" height=\"18\" fill=\"#7c3aed\" rx=\"2\"\/>\n<text x=\"475\" y=\"246\" class=\"gt-cap\" text-anchor=\"middle\">24 %<\/text>\n<rect x=\"640\" y=\"233\" width=\"50\" height=\"18\" fill=\"#dc2626\" rx=\"2\"\/>\n<text x=\"665\" y=\"246\" class=\"gt-cap\" text-anchor=\"middle\">5 %<\/text>\n<text x=\"20\" y=\"280\" class=\"gt-lbl\">PAC split charge &lt; 3 kg (HFC)<\/text>\n<rect x=\"530\" y=\"268\" width=\"115\" height=\"18\" fill=\"#94a3b8\" rx=\"2\"\/>\n<text x=\"587\" y=\"281\" class=\"gt-cap\" text-anchor=\"middle\">PRP \u2265 150 interdit d\u00e8s 2029<\/text>\n<text x=\"20\" y=\"350\" class=\"gt-src\">Source : R\u00e8glement (UE) 2024\/573 du Parlement europ\u00e9en et du Conseil du 7 f\u00e9vrier 2024 relatif aux gaz \u00e0 effet de serre fluor\u00e9s, Annexe IV.<\/text>\n<\/svg>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"quotas-hfc\">Le syst\u00e8me de quotas HFC<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le r\u00e8glement F-Gaz plafonne la production et l&rsquo;importation de HFC dans l&rsquo;UE selon un calendrier d\u00e9gressif exprim\u00e9 en tonnes \u00e9quivalent CO\u2082. Les quotas passent de 31 % de la ligne de base en 2024 \u00e0 24 % en 2027, puis chutent \u00e0 5 % en 2030 (<a href=\"https:\/\/eur-lex.europa.eu\/legal-content\/FR\/TXT\/?uri=CELEX:32024R0573\" target=\"_blank\" rel=\"noopener nofollow\">R\u00e8glement (UE) 2024\/573, Article 4 et Annexe V<\/a>). Le palier de 2030 est le vrai mur. Les r\u00e9frig\u00e9rants HFC qui \u00e9taient simplement chers en 2025 deviendront v\u00e9ritablement rares quand les quotas se resserreront. En pratique, chaque kilogramme de R-410A ou de R-454B consomme du quota, contrairement aux r\u00e9frig\u00e9rants naturels (R-290, R-744, R-717) qui en sont totalement exempt\u00e9s.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"interdictions-sectorielles\">Les interdictions sectorielles (Annexe IV)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">L&rsquo;Annexe IV du r\u00e8glement F-Gaz d\u00e9finit les dates d&rsquo;interdiction par cat\u00e9gorie d&rsquo;\u00e9quipement. Les principales \u00e9ch\u00e9ances sont : PRP \u2265 150 interdit pour les centrales multipack de plus de 40 kW depuis 2022 (d\u00e9j\u00e0 en vigueur), PRP \u2265 150 pour les meubles frigorifiques plug-in depuis janvier 2025, PRP \u2265 150 pour les splits AC et PAC split d\u00e8s janvier 2027, interdiction totale des HFC dans les PAC monobloc de charge \u2265 3 kg d\u00e8s janvier 2027, et PRP \u2265 150 pour les PAC split de charge inf\u00e9rieure \u00e0 3 kg en 2029. Les \u00e9quipements existants ne sont pas concern\u00e9s. Vous pouvez continuer \u00e0 entretenir un syst\u00e8me R-410A avec du gaz r\u00e9cup\u00e9r\u00e9 ou recycl\u00e9.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"attestation-capacite\">L&rsquo;attestation de capacit\u00e9 et la manipulation des fluides<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">En France, toute entreprise qui installe, entretient ou met hors service des \u00e9quipements contenant des gaz fluor\u00e9s doit d\u00e9tenir une <strong>attestation de capacit\u00e9<\/strong> d\u00e9livr\u00e9e par un organisme agr\u00e9\u00e9 (D\u00e9cret n\u00b0 2007-737, articles R543-75 \u00e0 R543-123 du Code de l&rsquo;environnement). Les techniciens intervenant directement sur le circuit frigorifique doivent \u00eatre titulaires d&rsquo;une <strong>attestation d&rsquo;aptitude<\/strong> individuelle. Les fuites doivent \u00eatre contr\u00f4l\u00e9es selon un calendrier bas\u00e9 sur la charge en tonnes \u00e9quivalent CO\u2082 : tous les 12 mois pour les syst\u00e8mes de 5 \u00e0 50 tonnes \u00e9q. CO\u2082, tous les 6 mois de 50 \u00e0 500, tous les 3 mois au-dessus de 500 (Article 5 du R\u00e8glement). Tout fluide r\u00e9cup\u00e9r\u00e9 doit \u00eatre remis \u00e0 un organisme de traitement agr\u00e9\u00e9.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"refrigerants-a2l\">R\u00e9frig\u00e9rants A2L : R-32 et R-454B<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Les deux r\u00e9frig\u00e9rants A2L qui portent la transition dans la climatisation r\u00e9sidentielle et tertiaire sont le R-32 (PRP 675) et le R-454B (PRP 466). En Europe, le R-32 domine nettement avec environ 55 % des nouvelles installations de splits et PAC en 2025, tir\u00e9 par Daikin depuis 2014 et suivi par Mitsubishi Electric, Panasonic, Toshiba et la plupart des constructeurs europ\u00e9ens (<a href=\"https:\/\/www.ehpa.org\/\" target=\"_blank\" rel=\"noopener nofollow\">EHPA \/ analyses de march\u00e9, 2025<\/a>). Tous deux sont faiblement inflammables, tous deux n\u00e9cessitent des outils certifi\u00e9s A2L, et tous deux seront impact\u00e9s par le seuil PRP 150 de 2027 pour les splits. Les crit\u00e8res de choix se r\u00e9sument \u00e0 la disponibilit\u00e9 OEM et \u00e0 la strat\u00e9gie de gamme.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"r32\">R-32 : le choix dominant en Europe<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le R-32 (difluorom\u00e9thane) est un composant unique avec un PRP de 675 et un glissement de temp\u00e9rature nul. Daikin l&rsquo;a pouss\u00e9 \u00e0 l&rsquo;\u00e9chelle mondiale depuis 2014 et l&#8217;embarque d\u00e9sormais dans la quasi-totalit\u00e9 de ses gammes split, multisplit et VRF. Mitsubishi Electric, Panasonic, Toshiba et les constructeurs europ\u00e9ens (Atlantic, Viessmann pour certaines gammes) ont suivi. L&rsquo;avantage en capacit\u00e9 est r\u00e9el : environ 5 \u00e0 8 % de puissance frigorifique suppl\u00e9mentaire par kilogramme par rapport au R-454B. En VRF, le R-32 est quasi-exclusif car la capacit\u00e9 sup\u00e9rieure compte davantage sur les circuits longs avec des charges plus importantes. Pour un guide d\u00e9taill\u00e9 sur le R-454B, son concurrent principal, consultez : <a href=\"https:\/\/refrigerationstore.eu\/fr\/gas\/r-454b-guide-complet-2026-composition-securite-a2l-et-reglement-f-gas\/\" rel=\"noopener\">What Is R-454B Refrigerant? Complete 2026 Guide<\/a> (en anglais).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"r454b\">R-454B : l&rsquo;option nord-am\u00e9ricaine pr\u00e9sente en Europe<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le R-454B est un m\u00e9lange z\u00e9otropique de 68,9 % de R-32 et 31,1 % de R-1234yf, avec un PRP de 466 et un faible glissement de temp\u00e9rature de 0,8 \u00e0 1,0 \u00b0C. Les constructeurs nord-am\u00e9ricains (Carrier, Trane, Johnson Controls, Lennox) l&rsquo;ont adopt\u00e9 comme standard parce que la marge sous le plafond am\u00e9ricain de 700 et l&rsquo;inflammabilit\u00e9 l\u00e9g\u00e8rement r\u00e9duite (LFL 11,8 % contre 14,4 % pour le R-32 pur) rassuraient leurs r\u00e9gulateurs. En Europe, le R-454B reste marginal dans les splits (environ 10 % du march\u00e9) mais trouve sa place dans certains \u00e9quipements import\u00e9s et dans les gammes Carrier \/ CIAT.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"refrigerants-naturels\">R\u00e9frig\u00e9rants Naturels : R-290, R-744 et R-717<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Les r\u00e9frig\u00e9rants naturels (R-290 propane, R-744 dioxyde de carbone, R-717 ammoniac) affichent des PRP inf\u00e9rieurs ou \u00e9gaux \u00e0 3 et ne sont pas soumis aux quotas HFC puisqu&rsquo;ils ne sont pas des HFC. Ils sont p\u00e9rennes d&rsquo;une mani\u00e8re que les A2L ne le sont pas. La contrepartie : chacun pr\u00e9sente une contrainte diff\u00e9rente. Le R-290 est hautement inflammable, le R-744 fonctionne \u00e0 des pressions extr\u00eames, et le R-717 est toxique \u00e0 faible concentration. Chacun domine l&rsquo;application qui correspond \u00e0 ses points forts.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"r290\">R-290 (propane) : meubles frigorifiques autonomes<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le R-290 est du propane purifi\u00e9 \u00e0 qualit\u00e9 frigorig\u00e8ne, avec un PRP de 3 et une classification de s\u00e9curit\u00e9 A3 (hautement inflammable). Les limites de charge le cantonnaient autrefois \u00e0 150 grammes, ce qui ne couvrait que les machines \u00e0 glace et les tr\u00e8s petits meubles. En 2019, l&rsquo;IEC a relev\u00e9 la limite \u00e0 500 grammes sous l&rsquo;IEC 60335-2-89, transpos\u00e9e dans la norme europ\u00e9enne harmonis\u00e9e EN IEC 60335-2-89:2022 (<a href=\"https:\/\/www.eptarefrigeration.com\/en\/newsroom\/news\/eu-harmonized-standard-en-iec-60335-2-892022-allowing-500-g-r290-propane-commercial\" target=\"_blank\" rel=\"noopener nofollow\">Epta Refrigeration, 2022<\/a>). Ce seul changement a ouvert la voie \u00e0 la majorit\u00e9 des meubles r\u00e9frig\u00e9r\u00e9s : vitrines, cong\u00e9lateurs, distributeurs automatiques, caves \u00e0 boissons. Les syst\u00e8mes doivent \u00eatre herm\u00e9tiquement scell\u00e9s (joints bras\u00e9s uniquement, pas de raccords dudgeon), et ils sont toujours autonomes : pas de lignes frigorifiques install\u00e9es sur site. L&rsquo;Europe est en avance : Epta, Carrier Commercial Refrigeration, Liebherr et De Rigo comptent des centaines de milliers d&rsquo;unit\u00e9s R-290 en service.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"r744\">R-744 (CO\u2082) : centrales transcritiques de supermarch\u00e9s<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le R-744 est le r\u00e9frig\u00e9rant dominant pour les nouvelles installations de froid commercial en grande distribution en Europe. Fin 2025, plus de 50 000 syst\u00e8mes transcritiques au CO\u2082 fonctionnaient dans le commerce de d\u00e9tail europ\u00e9en, notamment chez Carrefour, Monoprix, ALDI, Lidl, Tesco et Colruyt. Les conditions de fonctionnement sont exigeantes : pression critique de 74 bar (7,4 MPa), pression d&rsquo;\u00e9vaporateur autour de 35 bar, et pression du gas cooler pouvant atteindre 100 bar en mode transcritique. Cela exige une tuyauterie sp\u00e9ciale en cuivre-acier, des compresseurs multi-\u00e9tag\u00e9s et la technologie d&rsquo;\u00e9jecteur. Les modules multi-\u00e9jecteurs Danfoss augmentent le COP du syst\u00e8me de 15 \u00e0 25 % et ont rendu le transcritique viable dans les march\u00e9s \u00e0 climat chaud qui \u00e9taient auparavant hors limites, y compris le sud de la France et l&rsquo;Espagne.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"r717\">R-717 (ammoniac) : froid industriel et entreposage<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">L&rsquo;ammoniac assure la majorit\u00e9 du froid industriel europ\u00e9en (entrep\u00f4ts frigorifiques, transformation alimentaire, patinoires, refroidisseurs de grande capacit\u00e9) et cette part ne va pas bouger. Le R-717 affiche un PRP de 0, un ODP de 0, et d&rsquo;excellentes performances thermodynamiques, sans exposition aux quotas HFC. La contrepartie : sa classification de s\u00e9curit\u00e9 B2L signifie qu&rsquo;il est toxique \u00e0 des concentrations sup\u00e9rieures \u00e0 25 ppm et faiblement inflammable \u00e0 tr\u00e8s haute concentration. La norme EN 378 (Parties 1 \u00e0 4) encadre la conception, l&rsquo;installation, l&rsquo;exploitation et le d\u00e9mant\u00e8lement des installations au NH\u2083. Pour les grandes installations, la <a href=\"https:\/\/eur-lex.europa.eu\/legal-content\/FR\/TXT\/?uri=CELEX:32012L0018\" target=\"_blank\" rel=\"noopener nofollow\">directive Seveso III (2012\/18\/UE)<\/a> s&rsquo;applique \u00e0 partir de 50 tonnes de NH\u2083 (seuil bas) et 200 tonnes (seuil haut).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En 2026, l&rsquo;ammoniac perd du terrain dans les installations de taille moyenne (500 \u00e0 4 500 kg de charge) qui \u00e9chappaient aux r\u00e9gulations les plus lourdes. Les nouvelles exigences de ventilation de la salle des machines selon l&rsquo;EN 378-3 et les primes d&rsquo;assurance en hausse pour les petites installations poussent les concepteurs vers des syst\u00e8mes cascade NH\u2083\/CO\u2082. Ces derniers gardent la charge d&rsquo;ammoniac c\u00f4t\u00e9 haute pression sous les 500 kg et utilisent le CO\u2082 pour les circuits basse temp\u00e9rature en contact avec l&rsquo;espace r\u00e9frig\u00e9r\u00e9. Les cascades ajoutent de la complexit\u00e9 et du co\u00fbt d&rsquo;investissement, mais r\u00e9duisent suffisamment l&rsquo;inventaire d&rsquo;ammoniac pour \u00e9chapper aux exigences les plus contraignantes de Seveso et aux plans d&rsquo;urgence associ\u00e9s.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"melanges-transitionnels\">M\u00e9langes HFC de Transition : R-448A, R-449A, R-452A<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le R-448A (Solstice N40) et le R-449A (Opteon XP40) sont des m\u00e9langes HFO\/HFC avec des PRP de 1 273 et 1 397 respectivement, tous deux bien au-dessus du seuil de 150 pour les meubles et centrales, mais encore utilis\u00e9s en retrofit de syst\u00e8mes R-404A (PRP 3 922) dans le commerce alimentaire. Tous deux sont A1 (ininflammables). Ils existent comme \u00e9tapes transitoires pour les exploitants qui ne sont pas pr\u00eats \u00e0 passer directement au CO\u2082 transcritique ou au R-290.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Faut-il les sp\u00e9cifier en 2026 pour des syst\u00e8mes neufs ? Probablement pas, puisque les centrales multipack sont d\u00e9j\u00e0 limit\u00e9es \u00e0 PRP 150 et les plug-in depuis 2025. Pour les retrofits de syst\u00e8mes R-404A existants o\u00f9 le transcritique CO\u2082 impliquerait de remplacer toute la salle des machines, le calcul peut encore favoriser un m\u00e9lange de transition. Analysez soigneusement le co\u00fbt par rapport \u00e0 la dur\u00e9e de vie r\u00e9siduelle de l&rsquo;installation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"selection-application\">S\u00e9lection par Application<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">D&rsquo;apr\u00e8s les sp\u00e9cifications des \u00e9quipements neufs d\u00e9but 2026, le choix du r\u00e9frig\u00e9rant est devenu quasi d\u00e9terministe. Chaque application a d\u00e9sormais un choix par d\u00e9faut, avec une ou deux alternatives. Le tableau ci-dessous r\u00e9sume les recommandations pour les projets neufs, pond\u00e9r\u00e9es par la conformit\u00e9 au r\u00e8glement F-Gaz, la disponibilit\u00e9 des \u00e9quipements et le co\u00fbt total de possession sur 15 ans.<\/p>\n\n\n\n<figure class=\"chart-figure\" style=\"margin:1.5em 0;text-align:center;\">\n<svg viewBox=\"0 0 720 380\" role=\"img\" aria-label=\"Matrice d'ad\u00e9quation des r\u00e9frig\u00e9rants par application en Europe en 2026 : R-32, R-454B, R-290, R-744, R-717 et m\u00e9langes HFC\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" style=\"max-width:100%;height:auto;background:transparent;\">\n<style>.hm-ttl{font:700 14px system-ui,sans-serif;fill:currentColor;}.hm-app{font:600 11px system-ui,sans-serif;fill:currentColor;}.hm-ref{font:700 11px system-ui,sans-serif;fill:currentColor;text-anchor:middle;}.hm-key{font:600 10px system-ui,sans-serif;fill:#fff;text-anchor:middle;}.hm-src{font:10px system-ui,sans-serif;fill:currentColor;opacity:.65;}.hm-hd{font:700 10px system-ui,sans-serif;fill:currentColor;opacity:.7;text-anchor:middle;}<\/style>\n<text x=\"20\" y=\"24\" class=\"hm-ttl\">Ad\u00e9quation des r\u00e9frig\u00e9rants par application \u2014 Europe (2026)<\/text>\n<text x=\"295\" y=\"55\" class=\"hm-hd\">R-32<\/text>\n<text x=\"365\" y=\"55\" class=\"hm-hd\">R-454B<\/text>\n<text x=\"435\" y=\"55\" class=\"hm-hd\">R-290<\/text>\n<text x=\"505\" y=\"55\" class=\"hm-hd\">R-744<\/text>\n<text x=\"575\" y=\"55\" class=\"hm-hd\">R-717<\/text>\n<text x=\"645\" y=\"55\" class=\"hm-hd\">M\u00e9l. HFC<\/text>\n<!-- Residential AC \/ HP: R-32 Best, R-454B Alt -->\n<text x=\"20\" y=\"85\" class=\"hm-app\">AC r\u00e9sidentiel \/ PAC<\/text>\n<rect x=\"265\" y=\"70\" width=\"60\" height=\"22\" fill=\"#059669\" rx=\"2\"\/><text x=\"295\" y=\"85\" class=\"hm-key\">Opt.<\/text>\n<rect x=\"335\" y=\"70\" width=\"60\" height=\"22\" fill=\"#10b981\" rx=\"2\"\/><text x=\"365\" y=\"85\" class=\"hm-key\">Alt<\/text>\n<rect x=\"405\" y=\"70\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"435\" y=\"85\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"475\" y=\"70\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"505\" y=\"85\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"545\" y=\"70\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"575\" y=\"85\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"615\" y=\"70\" width=\"60\" height=\"22\" fill=\"#dc2626\" rx=\"2\"\/><text x=\"645\" y=\"85\" class=\"hm-key\">\u00c9viter<\/text>\n<!-- Light commercial AC: R-32 Best, R-454B Alt -->\n<text x=\"20\" y=\"115\" class=\"hm-app\">AC commercial l\u00e9ger<\/text>\n<rect x=\"265\" y=\"100\" width=\"60\" height=\"22\" fill=\"#059669\" rx=\"2\"\/><text x=\"295\" y=\"115\" class=\"hm-key\">Opt.<\/text>\n<rect x=\"335\" y=\"100\" width=\"60\" height=\"22\" fill=\"#10b981\" rx=\"2\"\/><text x=\"365\" y=\"115\" class=\"hm-key\">Alt<\/text>\n<rect x=\"405\" y=\"100\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"435\" y=\"115\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"475\" y=\"100\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"505\" y=\"115\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"545\" y=\"100\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"575\" y=\"115\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"615\" y=\"100\" width=\"60\" height=\"22\" fill=\"#dc2626\" rx=\"2\"\/><text x=\"645\" y=\"115\" class=\"hm-key\">\u00c9viter<\/text>\n<!-- VRF: R-32 Best, R-454B Alt -->\n<text x=\"20\" y=\"145\" class=\"hm-app\">VRF (tertiaire)<\/text>\n<rect x=\"265\" y=\"130\" width=\"60\" height=\"22\" fill=\"#059669\" rx=\"2\"\/><text x=\"295\" y=\"145\" class=\"hm-key\">Opt.<\/text>\n<rect x=\"335\" y=\"130\" width=\"60\" height=\"22\" fill=\"#10b981\" rx=\"2\"\/><text x=\"365\" y=\"145\" class=\"hm-key\">Alt<\/text>\n<rect x=\"405\" y=\"130\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"435\" y=\"145\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"475\" y=\"130\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"505\" y=\"145\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"545\" y=\"130\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"575\" y=\"145\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"615\" y=\"130\" width=\"60\" height=\"22\" fill=\"#dc2626\" rx=\"2\"\/><text x=\"645\" y=\"145\" class=\"hm-key\">\u00c9viter<\/text>\n<!-- Self-contained reach-ins: R-290 Best, R-744 Alt -->\n<text x=\"20\" y=\"175\" class=\"hm-app\">Meubles frigo. autonomes<\/text>\n<rect x=\"265\" y=\"160\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"295\" y=\"175\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"335\" y=\"160\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"365\" y=\"175\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"405\" y=\"160\" width=\"60\" height=\"22\" fill=\"#059669\" rx=\"2\"\/><text x=\"435\" y=\"175\" class=\"hm-key\">Opt.<\/text>\n<rect x=\"475\" y=\"160\" width=\"60\" height=\"22\" fill=\"#10b981\" rx=\"2\"\/><text x=\"505\" y=\"175\" class=\"hm-key\">Alt<\/text>\n<rect x=\"545\" y=\"160\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"575\" y=\"175\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"615\" y=\"160\" width=\"60\" height=\"22\" fill=\"#dc2626\" rx=\"2\"\/><text x=\"645\" y=\"175\" class=\"hm-key\">\u00c9viter<\/text>\n<!-- Supermarket centralized: R-744 Best, R-290 Alt -->\n<text x=\"20\" y=\"205\" class=\"hm-app\">Centrales de supermarch\u00e9s<\/text>\n<rect x=\"265\" y=\"190\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"295\" y=\"205\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"335\" y=\"190\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"365\" y=\"205\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"405\" y=\"190\" width=\"60\" height=\"22\" fill=\"#10b981\" rx=\"2\"\/><text x=\"435\" y=\"205\" class=\"hm-key\">Alt<\/text>\n<rect x=\"475\" y=\"190\" width=\"60\" height=\"22\" fill=\"#059669\" rx=\"2\"\/><text x=\"505\" y=\"205\" class=\"hm-key\">Opt.<\/text>\n<rect x=\"545\" y=\"190\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"575\" y=\"205\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"615\" y=\"190\" width=\"60\" height=\"22\" fill=\"#f59e0b\" rx=\"2\"\/><text x=\"645\" y=\"205\" class=\"hm-key\">Passerelle<\/text>\n<!-- Cold storage: R-717 Best, R-744 Alt -->\n<text x=\"20\" y=\"235\" class=\"hm-app\">Entreposage frigorifique<\/text>\n<rect x=\"265\" y=\"220\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"295\" y=\"235\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"335\" y=\"220\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"365\" y=\"235\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"405\" y=\"220\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"435\" y=\"235\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"475\" y=\"220\" width=\"60\" height=\"22\" fill=\"#10b981\" rx=\"2\"\/><text x=\"505\" y=\"235\" class=\"hm-key\">Alt<\/text>\n<rect x=\"545\" y=\"220\" width=\"60\" height=\"22\" fill=\"#059669\" rx=\"2\"\/><text x=\"575\" y=\"235\" class=\"hm-key\">Opt.<\/text>\n<rect x=\"615\" y=\"220\" width=\"60\" height=\"22\" fill=\"#dc2626\" rx=\"2\"\/><text x=\"645\" y=\"235\" class=\"hm-key\">\u00c9viter<\/text>\n<!-- Industrial process: R-717 Best, R-744 Alt -->\n<text x=\"20\" y=\"265\" class=\"hm-app\">Process industriel<\/text>\n<rect x=\"265\" y=\"250\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"295\" y=\"265\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"335\" y=\"250\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"365\" y=\"265\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"405\" y=\"250\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"435\" y=\"265\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"475\" y=\"250\" width=\"60\" height=\"22\" fill=\"#10b981\" rx=\"2\"\/><text x=\"505\" y=\"265\" class=\"hm-key\">Alt<\/text>\n<rect x=\"545\" y=\"250\" width=\"60\" height=\"22\" fill=\"#059669\" rx=\"2\"\/><text x=\"575\" y=\"265\" class=\"hm-key\">Opt.<\/text>\n<rect x=\"615\" y=\"250\" width=\"60\" height=\"22\" fill=\"#dc2626\" rx=\"2\"\/><text x=\"645\" y=\"265\" class=\"hm-key\">\u00c9viter<\/text>\n<!-- Mobile AC -->\n<text x=\"20\" y=\"295\" class=\"hm-app\">AC mobile \/ automobile<\/text>\n<rect x=\"265\" y=\"280\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"295\" y=\"295\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"335\" y=\"280\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"365\" y=\"295\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"405\" y=\"280\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"435\" y=\"295\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"475\" y=\"280\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"505\" y=\"295\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"545\" y=\"280\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"575\" y=\"295\" class=\"hm-key\">N\/A<\/text>\n<rect x=\"615\" y=\"280\" width=\"60\" height=\"22\" fill=\"#94a3b8\" rx=\"2\"\/><text x=\"645\" y=\"295\" class=\"hm-key\">R-1234yf<\/text>\n<!-- Legend -->\n<rect x=\"20\" y=\"325\" width=\"14\" height=\"14\" fill=\"#059669\"\/><text x=\"40\" y=\"336\" class=\"hm-app\">Optimal<\/text>\n<rect x=\"110\" y=\"325\" width=\"14\" height=\"14\" fill=\"#10b981\"\/><text x=\"130\" y=\"336\" class=\"hm-app\">Alternative<\/text>\n<rect x=\"210\" y=\"325\" width=\"14\" height=\"14\" fill=\"#f59e0b\"\/><text x=\"230\" y=\"336\" class=\"hm-app\">Passerelle<\/text>\n<rect x=\"320\" y=\"325\" width=\"14\" height=\"14\" fill=\"#dc2626\"\/><text x=\"340\" y=\"336\" class=\"hm-app\">\u00c9viter<\/text>\n<rect x=\"400\" y=\"325\" width=\"14\" height=\"14\" fill=\"#94a3b8\"\/><text x=\"420\" y=\"336\" class=\"hm-app\">N\/A<\/text>\n<text x=\"20\" y=\"370\" class=\"hm-src\">Source : Analyse \u00e9ditoriale du R\u00e8glement F-Gaz (UE) 2024\/573, EN IEC 60335-2-89, EN 378, sp\u00e9cifications OEM 2026.<\/text>\n<\/svg>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Quelques sch\u00e9mas de s\u00e9lection \u00e0 retenir. Les syst\u00e8mes VRF choisissent de plus en plus le R-32 parce que la capacit\u00e9 sup\u00e9rieure par kilogramme compte davantage sur les circuits longs avec des charges \u00e9lev\u00e9es. Les fabricants de meubles frigorifiques autonomes convertissent agressivement du R-404A au R-290 parce que la limite de 500 g couvre la majorit\u00e9 de leur catalogue. Les nouvelles constructions de supermarch\u00e9s sautent les m\u00e9langes HFC transitionnels et passent directement au CO\u2082 transcritique. La climatisation automobile a son propre \u00e9cosyst\u00e8me (R-1234yf depuis la directive MAC de l&rsquo;UE en 2017) et ne fait pas partie de la conversation sur le froid stationnaire.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"couts-outillage\">Co\u00fbts et R\u00e9alit\u00e9 de l&rsquo;Outillage<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">La transition de 2026 n&rsquo;est pas gratuite. Le R-454B a vu son prix de gros passer d&rsquo;environ 15 \u20ac\/kg en 2021 \u00e0 40-60 \u20ac\/kg d\u00e9but 2026 en Europe, port\u00e9 par la rar\u00e9faction des quotas HFC et la surcharge de 42 % annonc\u00e9e par Honeywell en avril 2025 (<a href=\"https:\/\/www.achrnews.com\/articles\/164475-honeywell-announces-42-surcharge-on-r-454b\" target=\"_blank\" rel=\"noopener nofollow\">ACHR News, 2025<\/a>). Le R-32 suit une trajectoire similaire car il est chimiquement soumis aux m\u00eames quotas. Les r\u00e9frig\u00e9rants naturels n&rsquo;ont pas cette pression tarifaire HFC, mais ils poussent les co\u00fbts vers l&rsquo;\u00e9quipement : un rack transcritique CO\u2082 co\u00fbte environ 15 \u00e0 25 % de plus qu&rsquo;un \u00e9quivalent HFC, et les contraintes r\u00e9glementaires de l&rsquo;ammoniac (EN 378, Seveso, ATEX) sont substantielles. Le march\u00e9 mondial des r\u00e9frig\u00e9rants \u00e0 faible PRP a d\u00e9pass\u00e9 12 milliards d&rsquo;euros en 2026 et devrait cro\u00eetre de 11 \u00e0 13 % par an jusqu&rsquo;en 2035.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"parts-marche\">Mix de r\u00e9frig\u00e9rants dans les nouvelles climatisations et PAC en Europe (2025)<\/h3>\n\n\n\n<figure class=\"chart-figure\" style=\"margin:1.5em 0;text-align:center;\">\n<svg viewBox=\"0 0 600 360\" role=\"img\" aria-label=\"Diagramme en anneau du mix de r\u00e9frig\u00e9rants dans les nouvelles climatisations et PAC en Europe en 2025 : R-32 55 pour cent, R-410A maintenance 25 pour cent, R-454B 10 pour cent, R-290 et naturels 10 pour cent\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" style=\"max-width:100%;height:auto;background:transparent;\">\n<style>.dn-ttl{font:700 14px system-ui,sans-serif;fill:currentColor;}.dn-key{font:600 12px system-ui,sans-serif;fill:currentColor;}.dn-pct{font:700 18px system-ui,sans-serif;fill:currentColor;text-anchor:middle;}.dn-sub{font:11px system-ui,sans-serif;fill:currentColor;opacity:.7;text-anchor:middle;}.dn-src{font:10px system-ui,sans-serif;fill:currentColor;opacity:.65;}<\/style>\n<text x=\"20\" y=\"24\" class=\"dn-ttl\">Mix r\u00e9frig\u00e9rants \u2014 nouvelles clim. et PAC en Europe (2025)<\/text>\n<g transform=\"translate(180,190)\">\n<!-- R-32: 55% = 345.58 of 628.32, starts at -90\u00b0 -->\n<circle r=\"100\" fill=\"none\" stroke=\"#059669\" stroke-width=\"40\" stroke-dasharray=\"345.58 628.32\" transform=\"rotate(-90)\"\/>\n<!-- R-410A maintenance: 25% = 157.08, starts at -90+198=108\u00b0 -->\n<circle r=\"100\" fill=\"none\" stroke=\"#dc2626\" stroke-width=\"40\" stroke-dasharray=\"157.08 628.32\" transform=\"rotate(108)\"\/>\n<!-- R-454B: 10% = 62.83, starts at 108+90=198\u00b0 -->\n<circle r=\"100\" fill=\"none\" stroke=\"#10b981\" stroke-width=\"40\" stroke-dasharray=\"62.83 628.32\" transform=\"rotate(198)\"\/>\n<!-- R-290 \/ naturels: 10% = 62.83, starts at 198+36=234\u00b0 -->\n<circle r=\"100\" fill=\"none\" stroke=\"#94a3b8\" stroke-width=\"40\" stroke-dasharray=\"62.83 628.32\" transform=\"rotate(234)\"\/>\n<text class=\"dn-pct\" y=\"0\">65 %<\/text>\n<text class=\"dn-sub\" y=\"20\">A2L + naturels<\/text>\n<\/g>\n<g transform=\"translate(360,100)\">\n<rect width=\"14\" height=\"14\" fill=\"#059669\"\/><text x=\"22\" y=\"12\" class=\"dn-key\">R-32 (55 %)<\/text>\n<rect y=\"28\" width=\"14\" height=\"14\" fill=\"#dc2626\"\/><text x=\"22\" y=\"40\" class=\"dn-key\">R-410A maintenance (25 %)<\/text>\n<rect y=\"56\" width=\"14\" height=\"14\" fill=\"#10b981\"\/><text x=\"22\" y=\"68\" class=\"dn-key\">R-454B (10 %)<\/text>\n<rect y=\"84\" width=\"14\" height=\"14\" fill=\"#94a3b8\"\/><text x=\"22\" y=\"96\" class=\"dn-key\">R-290 \/ naturels (10 %)<\/text>\n<\/g>\n<text x=\"20\" y=\"345\" class=\"dn-src\">Source : Estimations EHPA et analyses de march\u00e9 europ\u00e9en, 2025. Donn\u00e9es pour les climatiseurs split, PAC et VRF neufs.<\/text>\n<\/svg>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">C\u00f4t\u00e9 outillage, la plupart des frigoristes doivent ajouter trois \u00e9l\u00e9ments \u00e0 leur \u00e9quipement : un d\u00e9tecteur de fuites certifi\u00e9 A2L (le NDIR infrarouge est la norme sur le terrain), une station de r\u00e9cup\u00e9ration homologu\u00e9e EN IEC 60335-2-40 pour le service de classe 2L, et un manifold num\u00e9rique avec les profils R-32 et R-454B charg\u00e9s. Les pompes \u00e0 vide brushless \u00e9taient d\u00e9j\u00e0 courantes ; elles sont d\u00e9sormais indispensables. Pour les ateliers qui passent au CO\u2082, l&rsquo;outillage est bien plus cons\u00e9quent : bouteilles de r\u00e9cup\u00e9ration certifi\u00e9es 124 bar, pompes \u00e0 vide sans huile et d\u00e9tection de fuites sp\u00e9cifique au CO\u2082 \u00e0 faible concentration ambiante.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"normes-securite\">Normes de S\u00e9curit\u00e9 pour les R\u00e9frig\u00e9rants A2L et A3<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le passage aux r\u00e9frig\u00e9rants \u00e0 plus faible PRP a d\u00e9clench\u00e9 une vague de mises \u00e0 jour normatives parce que les profils d&rsquo;inflammabilit\u00e9 et de pression ont chang\u00e9. L&rsquo;EN IEC 60335-2-40 r\u00e9git les \u00e9quipements A2L pour la climatisation r\u00e9sidentielle et tertiaire et les PAC. L&rsquo;EN IEC 60335-2-89 couvre les meubles frigorifiques autonomes avec des r\u00e9frig\u00e9rants A3 (R-290, R-600a). L&rsquo;EN 378 (Parties 1 \u00e0 4) fixe le cadre pour les limites de charge en espace occup\u00e9. Les r\u00e9glementations nationales (en France, l&rsquo;arr\u00eat\u00e9 du 30 juin 2008 relatif aux installations de r\u00e9frig\u00e9ration) compl\u00e8tent le dispositif europ\u00e9en.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"limites-charge\">Limites de charge et syst\u00e8mes de d\u00e9tection de r\u00e9frig\u00e9rant<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li><strong>R-32 \/ R-454B (A2L)<\/strong> en AC r\u00e9sidentiel : les limites de charge d\u00e9pendent du volume de l&rsquo;espace conditionn\u00e9 et du type d&rsquo;\u00e9quipement ; les syst\u00e8mes de d\u00e9tection de r\u00e9frig\u00e9rant (RDS) sont obligatoires pour les unit\u00e9s int\u00e9rieures au-dessus du seuil calcul\u00e9 selon l&rsquo;EN IEC 60335-2-40.<\/li><li><strong>R-290 (A3)<\/strong> en meubles frigorifiques autonomes : 500 g maximum par circuit, scell\u00e9 herm\u00e9tiquement, pas de raccords dudgeon, composants \u00e9lectriques certifi\u00e9s pour atmosph\u00e8res potentiellement explosives (ATEX).<\/li><li><strong>R-744 (A1)<\/strong> : pas de limites de charge li\u00e9es \u00e0 l&rsquo;inflammabilit\u00e9, mais la pression de conception de 100 bar dicte pratiquement toutes les d\u00e9cisions d&rsquo;ing\u00e9nierie.<\/li><li><strong>R-717 (B2L)<\/strong> : les quantit\u00e9s de charge d\u00e9clenchent la directive Seveso III \u00e0 50 tonnes (seuil bas). R\u00e8gles de ventilation des espaces occup\u00e9s sous EN 378-3 et ventilation de la salle des machines sous EN 378-2.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Un point que nous rappelons r\u00e9guli\u00e8rement \u00e0 nos clients : le cadre normatif n&rsquo;est pas facultatif et ne se r\u00e9sume pas \u00e0 de la paperasse. Une installation A2L qui omet le capteur RDS ou utilise des relais non prot\u00e9g\u00e9s contre les \u00e9tincelles passe l&rsquo;inspection par chance, puis \u00e9choue au premier \u00e9v\u00e9nement de fuite. Idem pour les meubles R-290 livr\u00e9s avec des raccords \u00e0 dudgeon au lieu de joints bras\u00e9s, ce qui annule la certification CE sur-le-champ.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"apres-2026\">Et Apr\u00e8s 2026 : L&rsquo;Horizon Sub-150 PRP<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ne vous installez pas trop confortablement avec les seuils actuels. Le prochain palier du r\u00e8glement F-Gaz arrive en 2027 pour les splits AC (PRP \u2265 150 interdit), en 2029 pour les petites PAC split de charge inf\u00e9rieure \u00e0 3 kg, et le quota HFC tombe \u00e0 5 % de la ligne de base en 2030. Cette combinaison va pousser davantage d&rsquo;applications vers les r\u00e9frig\u00e9rants naturels et vers une nouvelle g\u00e9n\u00e9ration de HFO et HCFO qui commencent \u00e0 arriver sur le march\u00e9. Si vous sp\u00e9cifiez un \u00e9quipement avec une dur\u00e9e de vie de 15 ans aujourd&rsquo;hui, il est payant de comprendre ce qui arrive.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"hfo-prochaine-generation\">HFO et HCFO de nouvelle g\u00e9n\u00e9ration<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Trois r\u00e9frig\u00e9rants candidats sont dans le pipeline pour les applications sub-150 PRP : le R-471A (un m\u00e9lange HFO Honeywell avec un PRP inf\u00e9rieur \u00e0 150 ciblant la climatisation tertiaire), le R-1224yd(Z) (un HCFO Chemours avec un PRP de 1, utilis\u00e9 dans les refroidisseurs centrifuges), et le R-1233zd(E) (\u00e9galement un HCFO Chemours avec un PRP de 1, courant dans les refroidisseurs basse pression et les syst\u00e8mes ORC). Les HCFO portent une petite p\u00e9nalit\u00e9 chlor\u00e9e atmosph\u00e9rique mais se d\u00e9gradent rapidement dans la troposph\u00e8re, donnant un ODP effectif essentiellement nul. Attendez-vous \u00e0 les voir combler les niches que les A2L et les r\u00e9frig\u00e9rants naturels ne couvrent pas proprement, notamment les gros refroidisseurs de b\u00e2timents et les pompes \u00e0 chaleur industrielles.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"planifier-2030\">Planifier votre sp\u00e9cification pour les ann\u00e9es 2030<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Trois r\u00e8gles de bon sens pour les projets neufs en 2026. Premi\u00e8rement, quand les r\u00e9frig\u00e9rants naturels sont techniquement faisables (meubles autonomes \u00e0 faible charge, centrales de supermarch\u00e9s, froid industriel), choisissez-les. Ils sont d\u00e9finitivement exempt\u00e9s de la pression tarifaire HFC et des contraintes de quotas. Deuxi\u00e8mement, quand un A2L est la seule option, pr\u00e9f\u00e9rez le R-32 en Europe : il b\u00e9n\u00e9ficie d&rsquo;une base install\u00e9e plus large, d&rsquo;une disponibilit\u00e9 OEM sup\u00e9rieure, et d&rsquo;une capacit\u00e9 frigorifique par kilogramme plus \u00e9lev\u00e9e. Troisi\u00e8mement, \u00e9vitez les m\u00e9langes HFC transitionnels (R-448A, R-449A) pour les \u00e9quipements neufs, sauf si l&rsquo;alternative est de maintenir un syst\u00e8me R-404A en survie pour des ann\u00e9es. Ces m\u00e9langes deviendront chers bien avant d&rsquo;\u00eatre interdits formellement.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faq\">Questions Fr\u00e9quemment Pos\u00e9es<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Quel est le r\u00e9frig\u00e9rant avec le PRP le plus bas disponible en 2026 ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le R-744 (dioxyde de carbone) et le R-717 (ammoniac) sont les plus bas, avec des PRP de 1 et 0 respectivement. Le R-290 (propane) suit de pr\u00e8s \u00e0 3, et le R-1234yf (utilis\u00e9 en climatisation automobile) est \u00e0 4. Aucun d&rsquo;entre eux n&rsquo;est soumis aux quotas HFC puisqu&rsquo;ils ne sont pas des HFC. Ils sont p\u00e9rennes face \u00e0 tout durcissement futur des plafonds de PRP, mais chacun pr\u00e9sente des contraintes de manipulation qui le limitent \u00e0 des applications sp\u00e9cifiques.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Qu&rsquo;est-ce qu&rsquo;un r\u00e9frig\u00e9rant A2L ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A2L est la classification de s\u00e9curit\u00e9 ASHRAE Standard 34 pour les r\u00e9frig\u00e9rants de plus faible toxicit\u00e9 (Classe A) et de plus faible inflammabilit\u00e9 (2L). Ils ont une vitesse de combustion inf\u00e9rieure \u00e0 10 cm\/s et une LFL (limite inf\u00e9rieure d&rsquo;inflammabilit\u00e9) d&rsquo;au moins 3,5 % en volume. Le R-32 (LFL 14,4 %) et le R-454B (LFL 11,8 %) sont les r\u00e9frig\u00e9rants A2L dominants en 2026 pour la climatisation stationnaire. Faiblement inflammables, mais bien moins ignifiables que le propane (A3) ou le gaz naturel.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Comment la r\u00e9glementation F-Gaz \u00e9volue-t-elle en 2026 ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le r\u00e8glement r\u00e9vis\u00e9 (UE) 2024\/573 est entr\u00e9 en vigueur le 11 mars 2024. Il abaisse les quotas HFC (31 % en 2024, 24 % en 2027, 5 % en 2030), interdit les nouveaux split AC avec PRP \u2265 150 d\u00e8s janvier 2027, et impose des contr\u00f4les d&rsquo;\u00e9tanch\u00e9it\u00e9 renforc\u00e9s bas\u00e9s sur la charge en tonnes \u00e9quivalent CO\u2082. En France, l&rsquo;attestation de capacit\u00e9 et l&rsquo;attestation d&rsquo;aptitude restent obligatoires pour la manipulation des fluides frigorig\u00e8nes (D\u00e9cret n\u00b0 2007-737).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Quels sont les meilleurs r\u00e9frig\u00e9rants pour la climatisation commerciale en 2026 ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Cela d\u00e9pend de l&rsquo;application. La climatisation tertiaire et les PAC passent au R-32 ou au R-454B. Les nouvelles centrales de supermarch\u00e9s vont au CO\u2082 transcritique (R-744) pour respecter le plafond PRP 150 d\u00e9j\u00e0 en vigueur. Les meubles frigorifiques autonomes passent au R-290. Les entrep\u00f4ts frigorifiques et le process industriel restent au R-717 (ammoniac). Le R-448A et le R-449A servent de solutions transitoires pour les retrofits de syst\u00e8mes R-404A.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Pourquoi le R-290 (propane) est-il s\u00fbr dans les meubles frigorifiques ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le R-290 est hautement inflammable mais les limites de charge maintiennent l&rsquo;inventaire total de combustible en dessous du niveau n\u00e9cessaire pour cr\u00e9er une concentration dangereuse en int\u00e9rieur, m\u00eame apr\u00e8s un relargage total. Le plafond de 500 grammes par circuit sous l&rsquo;EN IEC 60335-2-89:2022, combin\u00e9 au scellement herm\u00e9tique, aux composants \u00e9lectriques anti-\u00e9tincelles et aux enceintes ventil\u00e9es, a produit un excellent bilan de s\u00e9curit\u00e9 sur des centaines de milliers d&rsquo;unit\u00e9s autonomes install\u00e9es en Europe.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Peut-on encore acheter et entretenir des \u00e9quipements au R-410A apr\u00e8s 2026 ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Oui pour l&rsquo;entretien, non pour les installations neuves. Le r\u00e8glement F-Gaz n&rsquo;interdit pas la maintenance des syst\u00e8mes R-410A existants. Le gaz r\u00e9cup\u00e9r\u00e9 et recycl\u00e9 reste disponible pour les recharges et r\u00e9parations. Toutefois, la rar\u00e9faction des quotas HFC fera monter les prix du R-410A vierge au fil des ans. Tout \u00e9quipement de remplacement devra utiliser un r\u00e9frig\u00e9rant conforme aux seuils de PRP en vigueur pour sa cat\u00e9gorie, comme le R-32 ou le R-454B.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Quelle est la diff\u00e9rence entre le CO\u2082 transcritique et subcritique ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le CO\u2082 subcritique reste en dessous du point critique de 7,4 MPa (74 bar) et se comporte comme un r\u00e9frig\u00e9rant conventionnel. Le transcritique fonctionne au-dessus de la pression critique c\u00f4t\u00e9 haute pression, ce que font la plupart des centrales de supermarch\u00e9s modernes parce que cela permet des gas coolers compacts et la r\u00e9cup\u00e9ration de chaleur. Le transcritique est plus difficile \u00e0 concevoir et fonctionne \u00e0 des pressions de gas cooler pouvant atteindre 100 bar, mais il monte mieux en puissance et fonctionne dans les climats chauds gr\u00e2ce \u00e0 la technologie multi-\u00e9jecteurs.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Le r\u00e8glement F-Gaz r\u00e9vis\u00e9 de 2024 modifie-t-il les d\u00e9lais en cours ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Oui, le r\u00e8glement (UE) 2024\/573 acc\u00e9l\u00e8re consid\u00e9rablement les \u00e9ch\u00e9ances par rapport \u00e0 la version de 2014. Les interdictions les plus imminentes concernent les splits AC (PRP \u2265 150 d\u00e8s janvier 2027) et les PAC monobloc \u00e0 charge \u2265 3 kg (HFC interdit en 2027). Le quota HFC \u00e0 5 % en 2030 est le changement structurel le plus radical. Certaines d\u00e9rogations existent pour les applications militaires et les semiconducteurs, mais elles ne concernent pas le froid commercial et la climatisation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"conclusion\">Ce qu&rsquo;il Faut Retenir sur les R\u00e9frig\u00e9rants \u00e0 Faible PRP en 2026<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le paysage europ\u00e9en des r\u00e9frig\u00e9rants en 2026 n&rsquo;est pas une seule transition, mais six. La climatisation r\u00e9sidentielle et tertiaire est en territoire A2L (R-32 principalement, R-454B en compl\u00e9ment). Les meubles frigorifiques autonomes appartiennent au R-290. Le froid commercial en grande distribution migre massivement vers le CO\u2082 transcritique. L&rsquo;entreposage frigorifique reste \u00e0 l&rsquo;ammoniac. Le process industriel garde l&rsquo;ammoniac ou passe en cascade NH\u2083\/CO\u2082. L&rsquo;automobile roule au R-1234yf depuis des ann\u00e9es. Choisissez le r\u00e9frig\u00e9rant qui correspond \u00e0 l&rsquo;application, planifiez l&rsquo;outillage et le travail normatif autour de la classe de s\u00e9curit\u00e9, et ne tentez pas de faire servir un seul fluide \u00e0 tous les usages. Cette \u00e9poque a pris fin avec le R-410A.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Besoin de bouteilles, d&rsquo;outillage certifi\u00e9 A2L ou de r\u00e9frig\u00e9rants naturels ? L&rsquo;\u00e9quipe <a href=\"https:\/\/refrigerationstore.eu\/fr\/contact\/\" rel=\"noopener\">Refrigeration Store<\/a> propose R-454B, R-32, R-290, R-448A et R-449A en bouteilles aux normes europ\u00e9ennes. Livraison sous 24 h dans l&rsquo;UE.<\/em><\/p>\n\n","protected":false},"excerpt":{"rendered":"<p>Un \u00ab r\u00e9frig\u00e9rant \u00e0 faible PRP (GWP) \u00bb en 2026, c&rsquo;est tout fluide frigorig\u00e8ne dont le Potentiel de R\u00e9chauffement Plan\u00e9taire se situe sous le seuil fix\u00e9 par le r\u00e8glement F-Gaz (UE) 2024\/573 pour sa cat\u00e9gorie d&rsquo;\u00e9quipement. Pour les climatiseurs split et les pompes \u00e0 chaleur (PAC), l&rsquo;interdiction vise un PRP sup\u00e9rieur ou \u00e9gal \u00e0 150 [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":5475,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[48],"tags":[],"class_list":["post-10370","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-gas"],"acf":[],"_links":{"self":[{"href":"https:\/\/refrigerationstore.eu\/fr\/wp-json\/wp\/v2\/posts\/10370","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/refrigerationstore.eu\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/refrigerationstore.eu\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/refrigerationstore.eu\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/refrigerationstore.eu\/fr\/wp-json\/wp\/v2\/comments?post=10370"}],"version-history":[{"count":1,"href":"https:\/\/refrigerationstore.eu\/fr\/wp-json\/wp\/v2\/posts\/10370\/revisions"}],"predecessor-version":[{"id":10371,"href":"https:\/\/refrigerationstore.eu\/fr\/wp-json\/wp\/v2\/posts\/10370\/revisions\/10371"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/refrigerationstore.eu\/fr\/wp-json\/wp\/v2\/media\/5475"}],"wp:attachment":[{"href":"https:\/\/refrigerationstore.eu\/fr\/wp-json\/wp\/v2\/media?parent=10370"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/refrigerationstore.eu\/fr\/wp-json\/wp\/v2\/categories?post=10370"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/refrigerationstore.eu\/fr\/wp-json\/wp\/v2\/tags?post=10370"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}