{"id":13741,"date":"2026-07-25T12:25:44","date_gmt":"2026-07-25T09:25:44","guid":{"rendered":"https:\/\/refrigerationstore.eu\/?p=13741"},"modified":"2026-07-30T19:44:14","modified_gmt":"2026-07-30T16:44:14","slug":"eu-hfc-phase-down-zeitplan-2025-2036","status":"publish","type":"post","link":"https:\/\/refrigerationstore.eu\/de\/gas\/eu-hfc-phase-down-zeitplan-2025-2036\/","title":{"rendered":"EU-HFC-Phase-Down-Zeitplan 2025\u20132036: Alle Fristen erkl\u00e4rt"},"content":{"rendered":"<p><!--\n================================================================\nWORDPRESS GUTENBERG BLOCKS - PASTE INTO POST BODY (Code Editor)\nTitle:  EU-HFC-Phase-Down-Zeitplan 2025\u20132036: Alle Fristen erkl\u00e4rt\nSlug:   eu-hfc-phase-down-zeitplan-2025-2036\nMeta:   Die EU-HFC-Quote sank 2025 um 48 %. Dieser Zeitplan erkl\u00e4rt alle Verbote, Wartungsbeschr\u00e4nkungen und Quoten-Meilensteine von 2025 bis 2036.\nAuthor: Refrigeration Store Redaktionsteam\nDate published: 2026-05-20\nDate modified: 2026-05-20\nCover image: https:\/\/images.pexels.com\/photos\/27134985\/pexels-photo-27134985.jpeg (Pexels, AC unit outside building)\n================================================================\n--><\/p>\n\n\n<p class=\"wp-block-paragraph\">Der EU-HFC-Phase-Down ist kein einzelnes Verbotsdatum. Es ist eine Treppe, und jede Stufe wird steiler. Die auf dem EU-Markt platzierten HFC-Mengen fielen innerhalb eines Jahres um 37 %, nachdem die \u00fcberarbeitete F-Gase-Verordnung in Kraft trat (<a href=\"https:\/\/www.eea.europa.eu\/en\/analysis\/indicators\/hydrofluorocarbon-phase-down-in-europe\" target=\"_blank\" rel=\"noopener nofollow\">Europ\u00e4ische Umweltagentur, 2025<\/a>). Dieser R\u00fcckgang war erst der Anfang.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Verordnung (EU) 2024\/573 ersetzte die urspr\u00fcnglichen Regeln von 2014 durch einen beschleunigten Zeitplan, der bis 2050 l\u00e4uft. Die sch\u00e4rfsten Einschnitte kommen jedoch zwischen 2025 und 2036. Jedes Jahr bringt eine andere Einschr\u00e4nkung: Verbote f\u00fcr bestimmte Ger\u00e4tekategorien hier, Wartungsgrenzen dort, Quotengeb\u00fchren und Produktionsobergrenzen an anderer Stelle. Das Ergebnis? Ein Flickenteppich, den selbst erfahrene K\u00e4lteanlagenbauer kaum noch \u00fcberblicken. Dieser Leitfaden geht jeden Meilenstein chronologisch durch, damit Sie genau sehen, was sich \u00e4ndert, wann es greift und was es f\u00fcr Ihren Betrieb bedeutet. Den vollst\u00e4ndigen regulatorischen Rahmen f\u00fcr alle K\u00e4ltemittel und Ger\u00e4tetypen finden Sie in unserem <a href=\"https:\/\/refrigerationstore.eu\/de\/gas\/eu-f-gas-verordnung-2026-r-32-r-454b-und-r-410a-leitfaden\/\">Leitfaden zur EU-F-Gase-Verordnung 2026<\/a>.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote key-takeaways is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Das Wichtigste auf einen Blick<\/strong><\/p>\n<\/blockquote>\n\n\n\n<h2 id=\"wie-phase-down-funktioniert\" class=\"wp-block-heading\">Wie funktioniert der EU-HFC-Phase-Down?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Die EU steuert den HFC-Verbrauch \u00fcber zwei parallele Mechanismen in Verordnung (EU) 2024\/573: ein Quotensystem (Anhang VII), das die Gesamtmenge der auf den Markt gebrachten HFKW begrenzt, und ger\u00e4tespezifische Verbote (Anhang IV), die bestimmte Produktkategorien oberhalb bestimmter GWP-Schwellenwerte untersagen (<a href=\"https:\/\/eur-lex.europa.eu\/eli\/reg\/2024\/573\" target=\"_blank\" rel=\"noopener nofollow\">EUR-Lex, Verordnung 2024\/573<\/a>). Die Quote \u00fcbernimmt die wirtschaftliche Hauptlast. Die Verbote greifen gezielt einzelne Ger\u00e4tekategorien heraus.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wie funktioniert die Quote in der Praxis? Jeder Hersteller und Importeur von HFKW-Massenware erh\u00e4lt eine Zuteilung, gemessen in CO\u2082-\u00c4quivalent-Tonnen, nicht in Kilogramm. Dieser Unterschied ist entscheidend, denn ein Gas mit hohem GWP wie R-404A (GWP 3.922) verbraucht die Quote fast sechsmal schneller als R-32 (GWP 675) bei gleicher Gasmenge. Der Ausgangswert liegt bei rund 176,7 Mt CO\u2082-\u00c4quivalent, basierend auf Marktdaten von 2015. Jeder Quotenzeitraum senkt das Maximum weiter.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><!-- [UNIQUE INSIGHT] -->Die Quote schr\u00e4nkt nicht direkt ein, was K\u00e4lteanlagenbauer beim Gro\u00dfh\u00e4ndler kaufen. Aber sie wirkt wie ein Trichter: Weniger Gas gelangt in jedem Zyklus auf den EU-Markt, also steigen die Preise und die Verf\u00fcgbarkeit sinkt. Fachbetriebe sp\u00fcren die Quote \u00fcber ihr Budget, nicht \u00fcber eine Kontrolle am Verkaufspunkt. Deshalb ist es genauso wichtig, den Quotenfahrplan zu verstehen wie die Verbotstermine zu kennen.<\/p>\n\n\n\n<figure class=\"chart-figure\" style=\"margin:1.5em 0;text-align:center;\">\n<svg viewBox=\"0 0 700 340\" role=\"img\" aria-label=\"Stufendiagramm des EU-HFC-Quotenabbaus von 100 % im Jahr 2015 auf ca. 5 % bis 2030 und nahezu null bis 2050\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" style=\"max-width:100%;height:auto;background:transparent;\">\n<style>.sa-ttl{font:700 14px system-ui,sans-serif;fill:currentColor;}.sa-sub{font:11px system-ui,sans-serif;fill:currentColor;opacity:.5;}.sa-lbl{font:600 10px system-ui,sans-serif;fill:currentColor;}.sa-val{font:700 11px system-ui,sans-serif;fill:currentColor;}.sa-yr{font:600 9px system-ui,sans-serif;fill:currentColor;opacity:.6;}.sa-src{font:10px system-ui,sans-serif;fill:currentColor;opacity:.35;}.sa-now{font:700 9px system-ui,sans-serif;}<\/style>\n<desc>Stufendiagramm des EU-HFC-Quotenabbaus gem\u00e4\u00df Verordnung 2024\/573 Anhang VII. Ausgangspunkt 100 % im Jahr 2015, Abstieg auf 93 % (2016), 63 % (2018), 45 % (2021), dann beschleunigt unter der neuen Verordnung auf ca. 24 % f\u00fcr 2025\u20132026, 12 % f\u00fcr 2027\u20132029 und 5 % ab 2030. Kigali-\u00c4nderung-Ziel von 15 % bis 2036 zum Vergleich dargestellt. Quelle: Verordnung (EU) 2024\/573 Anhang VII, Kigali-\u00c4nderung zum Montrealer Protokoll.<\/desc>\n<text x=\"350\" y=\"24\" class=\"sa-ttl\" text-anchor=\"middle\">EU-HFC-Quotenabbau: 2015\u20132036<\/text>\n<text x=\"350\" y=\"40\" class=\"sa-sub\" text-anchor=\"middle\">Maximale HFC-Mengen auf dem EU-Markt (% des Ausgangswerts 2015)<\/text>\n<!-- Grid lines -->\n<line x1=\"70\" y1=\"60\" x2=\"670\" y2=\"60\" stroke=\"currentColor\" stroke-width=\"0.5\" opacity=\".08\"\/>\n<line x1=\"70\" y1=\"110\" x2=\"670\" y2=\"110\" stroke=\"currentColor\" stroke-width=\"0.5\" opacity=\".08\"\/>\n<line x1=\"70\" y1=\"160\" x2=\"670\" y2=\"160\" stroke=\"currentColor\" stroke-width=\"0.5\" opacity=\".08\"\/>\n<line x1=\"70\" y1=\"210\" x2=\"670\" y2=\"210\" stroke=\"currentColor\" stroke-width=\"0.5\" opacity=\".08\"\/>\n<line x1=\"70\" y1=\"260\" x2=\"670\" y2=\"260\" stroke=\"currentColor\" stroke-width=\"0.5\" opacity=\".08\"\/>\n<!-- Y-axis labels -->\n<text x=\"62\" y=\"64\" class=\"sa-lbl\" text-anchor=\"end\">100%<\/text>\n<text x=\"62\" y=\"114\" class=\"sa-lbl\" text-anchor=\"end\">80%<\/text>\n<text x=\"62\" y=\"164\" class=\"sa-lbl\" text-anchor=\"end\">60%<\/text>\n<text x=\"62\" y=\"214\" class=\"sa-lbl\" text-anchor=\"end\">40%<\/text>\n<text x=\"62\" y=\"264\" class=\"sa-lbl\" text-anchor=\"end\">20%<\/text>\n<text x=\"62\" y=\"310\" class=\"sa-lbl\" text-anchor=\"end\">0%<\/text>\n<!-- Baseline axis -->\n<line x1=\"70\" y1=\"310\" x2=\"670\" y2=\"310\" stroke=\"currentColor\" stroke-width=\"1\" opacity=\".2\"\/>\n<line x1=\"70\" y1=\"60\" x2=\"70\" y2=\"310\" stroke=\"currentColor\" stroke-width=\"1\" opacity=\".2\"\/>\n<!-- Stepped area fill -->\n<path d=\"M70,60 L70,60 L150,60 L150,77.5 L230,77.5 L230,147.5 L340,147.5 L340,185 L410,185 L410,250 L480,250 L480,285 L670,285 L670,310 L70,310 Z\" fill=\"#f97316\" opacity=\".15\"\/>\n<!-- Stepped area line -->\n<path d=\"M70,60 L150,60 L150,77.5 L230,77.5 L230,147.5 L340,147.5 L340,185 L410,185 L410,250 L480,250 L480,285 L670,285\" fill=\"none\" stroke=\"#f97316\" stroke-width=\"2.5\"\/>\n<!-- Step dots and labels -->\n<!-- 2015: 100% -->\n<circle cx=\"70\" cy=\"60\" r=\"4\" fill=\"#f97316\"\/>\n<text x=\"70\" y=\"53\" class=\"sa-val\" text-anchor=\"start\">100%<\/text>\n<!-- 2016: 93% -->\n<circle cx=\"150\" cy=\"77.5\" r=\"3\" fill=\"#f97316\"\/>\n<text x=\"155\" y=\"73\" class=\"sa-val\" text-anchor=\"start\" font-size=\"9\">93%<\/text>\n<!-- 2018: 63% -->\n<circle cx=\"230\" cy=\"147.5\" r=\"3\" fill=\"#f97316\"\/>\n<text x=\"235\" y=\"143\" class=\"sa-val\" text-anchor=\"start\" font-size=\"9\">63%<\/text>\n<!-- 2021: 45% -->\n<circle cx=\"340\" cy=\"185\" r=\"3\" fill=\"#f97316\"\/>\n<text x=\"345\" y=\"181\" class=\"sa-val\" text-anchor=\"start\" font-size=\"9\">45%<\/text>\n<!-- 2025: ~24% \u2014 NOW marker -->\n<circle cx=\"410\" cy=\"250\" r=\"5\" fill=\"#f97316\" stroke=\"#fff\" stroke-width=\"2\"\/>\n<text x=\"410\" y=\"242\" class=\"sa-now\" text-anchor=\"middle\" fill=\"#f97316\">~24%<\/text>\n<text x=\"410\" y=\"232\" class=\"sa-now\" text-anchor=\"middle\" fill=\"#f97316\">SIE SIND HIER<\/text>\n<!-- 2027: ~12% -->\n<circle cx=\"480\" cy=\"280\" r=\"3\" fill=\"#f97316\"\/>\n<text x=\"485\" y=\"276\" class=\"sa-val\" text-anchor=\"start\" font-size=\"9\">~12%<\/text>\n<!-- 2030: 5% -->\n<circle cx=\"560\" cy=\"297.5\" r=\"3\" fill=\"#f97316\"\/>\n<text x=\"565\" y=\"293\" class=\"sa-val\" text-anchor=\"start\" font-size=\"9\">5%<\/text>\n<!-- Kigali comparison dashed line at 15% -->\n<line x1=\"410\" y1=\"272.5\" x2=\"670\" y2=\"272.5\" stroke=\"#38bdf8\" stroke-width=\"1.5\" stroke-dasharray=\"6,3\"\/>\n<text x=\"672\" y=\"276\" class=\"sa-lbl\" text-anchor=\"start\" fill=\"#38bdf8\" font-size=\"8\">Kigali 15%<\/text>\n<text x=\"672\" y=\"286\" class=\"sa-lbl\" text-anchor=\"start\" fill=\"#38bdf8\" font-size=\"8\">(Ziel 2036)<\/text>\n<!-- X-axis year labels -->\n<text x=\"70\" y=\"325\" class=\"sa-yr\" text-anchor=\"middle\">2015<\/text>\n<text x=\"150\" y=\"325\" class=\"sa-yr\" text-anchor=\"middle\">2016<\/text>\n<text x=\"230\" y=\"325\" class=\"sa-yr\" text-anchor=\"middle\">2018<\/text>\n<text x=\"340\" y=\"325\" class=\"sa-yr\" text-anchor=\"middle\">2021<\/text>\n<text x=\"410\" y=\"325\" class=\"sa-yr\" text-anchor=\"middle\">2025<\/text>\n<text x=\"480\" y=\"325\" class=\"sa-yr\" text-anchor=\"middle\">2027<\/text>\n<text x=\"560\" y=\"325\" class=\"sa-yr\" text-anchor=\"middle\">2030<\/text>\n<text x=\"640\" y=\"325\" class=\"sa-yr\" text-anchor=\"middle\">2036<\/text>\n<!-- Source -->\n<text x=\"350\" y=\"338\" class=\"sa-src\" text-anchor=\"middle\">Quelle: Verordnung (EU) 2024\/573, Anhang VII | Kigali-\u00c4nderung (Montrealer Protokoll) | Diagramm: refrigerationstore.eu<\/text>\n<\/svg>\n<figcaption style=\"font-size:0.85em;color:#6b7280;margin-top:0.5rem;\">EU-HFC-Quotenabbau von 100 % Ausgangswert (2015) bis nahezu null. Die blaue gestrichelte Linie markiert das 15-%-Ziel der Kigali-\u00c4nderung f\u00fcr Industriel\u00e4nder bis 2036. Die EU erreicht 5 % bereits 2030, sechs Jahre vor dem internationalen Richtwert.<\/figcaption>\n<\/figure>\n\n\n\n<h2 id=\"2024-2026\" class=\"wp-block-heading\">2024\u20132026: Wo stehen wir jetzt?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Die HFC-Quote f\u00fcr 2025\u20132026 liegt bei 42,9 Mt CO\u2082-\u00c4quivalent, eine K\u00fcrzung um 48 % gegen\u00fcber dem Niveau von 2023 mit 82,3 Mt (<a href=\"https:\/\/ifra-kaelte.de\/en\/news\/f-gas-phase-down-roadmap\/\" target=\"_blank\" rel=\"noopener nofollow\">IFRA K\u00e4ltetechnik, 2025<\/a>). Das ist bereits sp\u00fcrbar. Die urspr\u00fcngliche Verordnung von 2014 sah eine sanftere Absenkung vor. Die \u00fcberarbeitete Fassung 2024\/573 hat den Zeitplan beschleunigt und k\u00fcnftige K\u00fcrzungen in die Gegenwart vorgezogen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Folgendes gilt bereits oder tritt in diesem Jahr in Kraft:<\/p>\n\n\n\n<!-- [ORIGINAL DATA] -->\n<figure style=\"margin:1.5em 0;overflow-x:auto;\">\n<table style=\"width:100%;border-collapse:collapse;font-size:0.92em;line-height:1.5;\">\n<thead>\n<tr style=\"background:#1e293b;color:#fff;\">\n<th style=\"padding:10px 14px;text-align:left;\">Datum<\/th>\n<th style=\"padding:10px 14px;text-align:left;\">Was sich \u00e4ndert<\/th>\n<th style=\"padding:10px 14px;text-align:left;\">Wer betroffen ist<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"border-bottom:1px solid #e2e8f0;\">\n<td style=\"padding:10px 14px;font-weight:700;\">Jan. 2025<\/td>\n<td style=\"padding:10px 14px;\">Neue Einzel-Split-Klimaanlagen und W\u00e4rmepumpen mit &lt;3 kg F\u00fcllmenge: GWP muss unter 750 liegen<\/td>\n<td style=\"padding:10px 14px;\">R-410A (GWP 1.924) f\u00fcr neue Ger\u00e4te in dieser Kategorie verboten<\/td>\n<\/tr>\n<tr style=\"border-bottom:1px solid #e2e8f0;background:#f8fafc;\">\n<td style=\"padding:10px 14px;font-weight:700;\">Jan. 2025<\/td>\n<td style=\"padding:10px 14px;\">Steckerfertige gewerbliche K\u00e4ltetechnik (Plug-in): GWP muss unter 150 liegen<\/td>\n<td style=\"padding:10px 14px;\">R-134a (GWP 1.430) und R-404A (GWP 3.922) f\u00fcr neue Plug-in-Ger\u00e4te verboten<\/td>\n<\/tr>\n<tr style=\"border-bottom:1px solid #e2e8f0;\">\n<td style=\"padding:10px 14px;font-weight:700;\">Jan. 2025<\/td>\n<td style=\"padding:10px 14px;\">Exportverbot f\u00fcr RACHP-Systeme, die f\u00fcr K\u00e4ltemittel mit GWP \u22651.000 ausgelegt sind<\/td>\n<td style=\"padding:10px 14px;\">EU-Hersteller, die Ger\u00e4te mit hohem GWP exportieren<\/td>\n<\/tr>\n<tr style=\"border-bottom:1px solid #e2e8f0;background:#f8fafc;\">\n<td style=\"padding:10px 14px;font-weight:700;\">Jan. 2025<\/td>\n<td style=\"padding:10px 14px;\">Neue Kennzeichnungspflichten f\u00fcr fluorierte Gase (HFKW, HFO, HCFO)<\/td>\n<td style=\"padding:10px 14px;\">Alle Hersteller, Importeure und H\u00e4ndler<\/td>\n<\/tr>\n<tr style=\"border-bottom:1px solid #e2e8f0;\">\n<td style=\"padding:10px 14px;font-weight:700;\">Jan. 2026<\/td>\n<td style=\"padding:10px 14px;\">Wartungsverbot: Ungebrauchte HFKW mit GWP \u22652.500 f\u00fcr die Wartung von Klima-\/W\u00e4rmepumpenanlagen verboten<\/td>\n<td style=\"padding:10px 14px;\">R-404A und R-507A f\u00fcr die Wartung verboten. R-410A (GWP 1.924) bleibt zul\u00e4ssig<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px 14px;font-weight:700;\">Jan. 2026<\/td>\n<td style=\"padding:10px 14px;\">Quotengeb\u00fchr von 3 EUR pro Tonne CO\u2082-\u00c4quivalent eingef\u00fchrt (Artikel 17)<\/td>\n<td style=\"padding:10px 14px;\">Erh\u00f6ht die Kosten f\u00fcr ungebrauchtes R-410A um ca. 6 EUR\/kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figcaption style=\"font-size:0.85em;color:#6b7280;margin-top:0.5rem;\">Quelle: Verordnung (EU) 2024\/573, Anhang IV &amp; Artikel 11, 17. GWP-Werte gem\u00e4\u00df IPCC AR5.<\/figcaption>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Die unmittelbare Auswirkung ist klar: R-404A ist sowohl f\u00fcr neue Ger\u00e4te als auch f\u00fcr die Wartung in der EU praktisch Geschichte. R-410A \u00fcberlebt f\u00fcr die Wartung bestehender Anlagen, aber die Quotengeb\u00fchr hebt die Preisuntergrenze an. Sie m\u00f6chten genau wissen, wo R-410A steht? Unser <a href=\"https:\/\/refrigerationstore.eu\/de\/gas\/ist-r-410a-in-der-eu-verboten-2026\/\">Leitfaden zum Status von R-410A in der EU 2026<\/a> erl\u00e4utert den Unterschied zwischen ungebrauchtem und recyceltem K\u00e4ltemittel im Detail.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"701\" src=\"https:\/\/refrigerationstore.eu\/wp-content\/uploads\/2026\/07\/Commercial-HVAC-condensing-unit-1024x701.png\" alt=\"\" class=\"wp-image-13716\" srcset=\"https:\/\/refrigerationstore.eu\/wp-content\/uploads\/2026\/07\/Commercial-HVAC-condensing-unit-1024x701.png 1024w, https:\/\/refrigerationstore.eu\/wp-content\/uploads\/2026\/07\/Commercial-HVAC-condensing-unit-300x205.png 300w, https:\/\/refrigerationstore.eu\/wp-content\/uploads\/2026\/07\/Commercial-HVAC-condensing-unit-768x525.png 768w, https:\/\/refrigerationstore.eu\/wp-content\/uploads\/2026\/07\/Commercial-HVAC-condensing-unit-1536x1051.png 1536w, https:\/\/refrigerationstore.eu\/wp-content\/uploads\/2026\/07\/Commercial-HVAC-condensing-unit-2048x1401.png 2048w, https:\/\/refrigerationstore.eu\/wp-content\/uploads\/2026\/07\/Commercial-HVAC-condensing-unit-600x411.png 600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 id=\"2027-wendepunkt\" class=\"wp-block-heading\">2027: Warum ist dieses Jahr der gr\u00f6\u00dfte Wendepunkt?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Die Quote sinkt f\u00fcr 2027\u20132029 auf rund 12 % des Ausgangswerts von 2015, und eine neue Runde von Verboten nach Anhang IV tritt in Kraft, die den Markt f\u00fcr Wohnraumklimatisierung grundlegend ver\u00e4ndert (<a href=\"https:\/\/eur-lex.europa.eu\/eli\/reg\/2024\/573\" target=\"_blank\" rel=\"noopener nofollow\">EUR-Lex, Verordnung 2024\/573, Anhang IV<\/a>). Der Januar 2027 ist das Datum, das die Branche bei R-32 zum Handeln zwingt.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Was passiert konkret? Die GWP-Obergrenze f\u00fcr neue Split-Klimaanlagen bis 12 kW und alle Monoblockger\u00e4te sinkt auf 150. R-32 mit einem GWP von 675 darf dann nicht mehr in neue kleine Wohnraumger\u00e4te eingebaut werden. R-454B (GWP 466) f\u00e4llt ebenfalls durch. Nur K\u00e4ltemittel unter GWP 150 kommen infrage: R-290 (Propan, GWP 3) f\u00fcr die meisten Anwendungen oder R-32 in gr\u00f6\u00dferen Systemen, die oberhalb der 12-kW-Schwelle liegen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><!-- [PERSONAL EXPERIENCE] -->Warum ist 2027 wichtiger als 2025? Die Verbote von 2025 betrafen nur Einzel-Splits unter 3 kg F\u00fcllmenge, ein schmales Marktsegment. Die Verbote von 2027 erfassen alles bis 12 kW, und das deckt den Gro\u00dfteil der Wohnraumklimatisierung und kleiner Gewerbeanlagen in Europa ab. Wenn Sie Ger\u00e4te f\u00fcr ein Projekt spezifizieren, das Ende 2026 oder 2027 installiert wird, m\u00fcssen Sie bereits jetzt f\u00fcr den 150er-Grenzwert planen, nicht f\u00fcr den aktuellen von 750.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dazu kommt ein praktisches Problem. R-290-Systeme unterliegen <a href=\"https:\/\/refrigerationstore.eu\/de\/gas\/kaeltemitteltyp-ihrer-klimaanlage-finden-vollstaendiger-leitfaden-2026\/\">F\u00fcllmengenbegrenzungen nach EN IEC 60335-2-89<\/a>, die die zul\u00e4ssige Propanmenge pro K\u00e4ltekreislauf begrenzen. Bei h\u00f6heren Leistungsanforderungen bedeutet das mehrere Kreisl\u00e4ufe oder andere Systemarchitekturen. Die Frist 2027 ist nicht nur ein K\u00e4ltemitteltausch. Sie erfordert ein Umdenken beim Anlagendesign.<\/p>\n\n\n\n<h2 id=\"2029-2032\" class=\"wp-block-heading\">2029\u20132032: Der Weg zum Nahezu-Nullpunkt<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ab 2030 sinkt die EU-HFC-Quote auf nur noch 5 % des Ausgangswerts von 2015, rund 9 Mt CO\u2082-\u00c4quivalent pro Jahr. Das ist eine Reduktion um 95 % gegen\u00fcber dem Startwert (<a href=\"https:\/\/climate.ec.europa.eu\/eu-action\/fluorinated-greenhouse-gases\/f-gas-legislation_en\" target=\"_blank\" rel=\"noopener nofollow\">Europ\u00e4ische Kommission, F-Gase-Gesetzgebung<\/a>). Bei 5 % wird ungebrauchtes HFKW zu einem Nischenprodukt: teuer und knapp. Die einzelnen Schritte im \u00dcberblick:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Januar 2029:<\/strong> Hermetisch geschlossene gewerbliche K\u00fchl- und Gefrierger\u00e4te m\u00fcssen K\u00e4ltemittel mit einem GWP unter 150 verwenden. Dies betrifft die verbleibenden Kategorien, die von den Verboten 2022 und 2025 nicht erfasst wurden. Hersteller hermetischer Verdichter haben bereits weitgehend auf R-290 und R-600a (Isobutan) umgestellt, aber dieses Datum macht es zur Pflicht.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Januar 2030:<\/strong> Die Quotenklippe kommt. Die Versorgung mit ungebrauchtem HFKW schrumpft auf ein Zwanzigstel des Niveaus von 2015. Zur Einordnung: Der EU-HFKW-Markt lag 2023 bei 82,3 Mt CO\u2082-\u00c4quivalent. Bis 2030 betr\u00e4gt die gesamte Jahresquote etwa 9 Mt. Der Markt f\u00fcr recyceltes und r\u00fcckgewonnenes K\u00e4ltemittel ist dann keine Option mehr. Er wird zum Hauptversorgungskanal.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Januar 2032:<\/strong> Der GWP-Grenzwert f\u00fcr die Wartung von Klima- und W\u00e4rmepumpenanlagen sinkt von 2.500 auf 750 (<a href=\"https:\/\/www.danfoss.com\/en\/about-danfoss\/our-businesses\/cooling\/refrigerants-and-energy-efficiency\/hfc-phase-down\/danfoss-on-f-gas-regulation\/\" target=\"_blank\" rel=\"noopener nofollow\">Danfoss, Zeitplan zur F-Gase-Verordnung<\/a>). Dies ist der Stichtag, der die Wartung mit ungebrauchtem R-410A endg\u00fcltig beendet. Mit einem GWP von 1.924 liegt R-410A unter dem aktuellen Schwellenwert von 2.500, aber 750 kann es nicht unterschreiten. Ab 2032 ist selbst die Wartung einer bestehenden R-410A-Anlage mit Neuware illegal. Recyceltes und r\u00fcckgewonnenes R-410A bleibt gem\u00e4\u00df Artikel 8 weiterhin erlaubt.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><!-- [UNIQUE INSIGHT] -->Diese Wartungsfrist 2032 ist der Termin, f\u00fcr den die meisten noch nicht geplant haben. K\u00e4lteanlagenbauer, die ungebrauchtes R-410A f\u00fcr die Wartung eingelagert haben, sollten wissen: Es hat eine Haltbarkeit, nicht chemisch, aber rechtlich. Ab 2032 bleibt als einzige Option f\u00fcr R-410A-Nachf\u00fcllungen r\u00fcckgewonnenes Gas nach AHRI-700-Standard. Haben Sie bereits Kontakte zu zertifizierten R\u00fcckgewinnungsbetrieben aufgebaut? Jetzt ist der richtige Zeitpunkt.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"701\" src=\"https:\/\/refrigerationstore.eu\/wp-content\/uploads\/2026\/07\/R_sidentiel-_-groupe-de-condensation-mural-1024x701.png\" alt=\"\" class=\"wp-image-13731\" srcset=\"https:\/\/refrigerationstore.eu\/wp-content\/uploads\/2026\/07\/R_sidentiel-_-groupe-de-condensation-mural-1024x701.png 1024w, https:\/\/refrigerationstore.eu\/wp-content\/uploads\/2026\/07\/R_sidentiel-_-groupe-de-condensation-mural-300x205.png 300w, https:\/\/refrigerationstore.eu\/wp-content\/uploads\/2026\/07\/R_sidentiel-_-groupe-de-condensation-mural-768x525.png 768w, https:\/\/refrigerationstore.eu\/wp-content\/uploads\/2026\/07\/R_sidentiel-_-groupe-de-condensation-mural-1536x1051.png 1536w, https:\/\/refrigerationstore.eu\/wp-content\/uploads\/2026\/07\/R_sidentiel-_-groupe-de-condensation-mural-2048x1401.png 2048w, https:\/\/refrigerationstore.eu\/wp-content\/uploads\/2026\/07\/R_sidentiel-_-groupe-de-condensation-mural-600x411.png 600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 id=\"2033-2036-kigali\" class=\"wp-block-heading\">2033\u20132036 und die Kigali-\u00c4nderung<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Die Kigali-\u00c4nderung zum Montrealer Protokoll verpflichtet Industriel\u00e4nder, den HFKW-Verbrauch bis 2036 auf 15 % ihres Ausgangswerts zu senken (<a href=\"https:\/\/en.wikipedia.org\/wiki\/Kigali_Amendment\" target=\"_blank\" rel=\"noopener nofollow\">UNEP, Kigali-\u00c4nderung<\/a>). Das 5-%-Ziel der EU ab 2030 \u00fcbertrifft diese Vorgabe um ein Jahrzehnt. Was passiert also nach 2030?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die Verordnung h\u00e4lt das 5-%-Quotenniveau bis mindestens 2036 aufrecht. Zwischen 2030 und 2036 ist keine weitere Absenkung geplant, weil es kaum noch etwas zu k\u00fcrzen gibt. Die verbleibenden 5 % dienen haupts\u00e4chlich industriellen Nischenanwendungen, milit\u00e4rischer Alttechnik und Spezialzwecken, f\u00fcr die noch keine praktikable Alternative existiert.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00dcber 2036 hinaus weist die Entwicklung in Richtung eines vollst\u00e4ndigen Ausstiegs. Verordnung 2024\/573 zielt auf die Abschaffung des Einsatzes von ungebrauchtem HFKW bis 2050 (<a href=\"https:\/\/ecostandard.org\/wp-content\/uploads\/2024\/01\/ECOS_240125_F-Gas_Factsheet_FINAL.pdf\" target=\"_blank\" rel=\"noopener nofollow\">ECOS, F-Gase-Factsheet, 2024<\/a>). Zu diesem Zeitpunkt sollten nur noch r\u00fcckgewonnene Best\u00e4nde aus stillgelegten Anlagen im Umlauf sein. F\u00fcr alle, die heute Anlagen installieren, ist diese Zukunft bereits die Planungsgrundlage: nat\u00fcrliche K\u00e4ltemittel (R-290, R-744, R-717) oder Ultra-Niedrig-GWP-Synthetika (R-1234yf, R-1234ze) f\u00fcr Neuanlagen und r\u00fcckgewonnenes HFKW f\u00fcr die Wartung des schrumpfenden Anlagenbestands.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wie sieht es im Vergleich zu den USA aus? Der AIM Act folgt denselben Kigali-Zielen, allerdings ohne die ger\u00e4tespezifischen Verbote der EU. Unser <a href=\"https:\/\/refrigerationstore.eu\/de\/gas\/kaeltemittel-mit-niedrigem-gwp-leitfaden-2026-fuer-r-454b-r-32-und-mehr\/\">Leitfaden zu K\u00e4ltemitteln mit niedrigem GWP 2026<\/a> stellt den Ansatz der EPA dem EU-Rahmen gegen\u00fcber.<\/p>\n\n\n\n<h2 id=\"preisauswirkungen\" class=\"wp-block-heading\">Wie wirkt sich das auf den K\u00e4ltemittelpreis aus?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ungebrauchtes R-410A wird in der EU bereits zu 40 bis 48 EUR pro Kilogramm gehandelt, bezogen auf 10-kg-Flaschen (\u00d6ko-Recherche f\u00fcr die Europ\u00e4ische Kommission, Q4 2025). Die neue Quotengeb\u00fchr aus Artikel 17 der Verordnung 2024\/573 kommt ab Januar 2026 mit 3 EUR pro Tonne CO\u2082-\u00c4quivalent hinzu. F\u00fcr R-410A bedeutet das zus\u00e4tzliche Kosten von rund 5,77 EUR pro Kilogramm auf den Marktpreis (<a href=\"https:\/\/eur-lex.europa.eu\/eli\/reg\/2024\/573\" target=\"_blank\" rel=\"noopener nofollow\">EUR-Lex, Artikel 17<\/a>).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die Rechnung ist einfach: Jede Quotenstufe verringert das Angebot, und sinkendes Angebot treibt die Preise nach oben. R-32 kostet in der EU rund 15 bis 22 EUR pro Kilogramm, weniger als die H\u00e4lfte von R-410A. R-290 (Propan) ist noch g\u00fcnstiger, typischerweise 3 bis 8 EUR pro Kilogramm, wobei die Anlagenkosten wegen der Sicherheitsanforderungen f\u00fcr brennbare K\u00e4ltemittel h\u00f6her ausfallen. M\u00f6chten Sie Ersatzoptionen im Detail vergleichen? Unser <a href=\"https:\/\/refrigerationstore.eu\/de\/gas\/r-454b-kaeltemittel-2026-zusammensetzung-a2l-sicherheit-und-eu-f-gas-verordnung\/\">R-454B-Leitfaden<\/a> beleuchtet die gesamte Kostenstruktur f\u00fcr A2L-Alternativen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><!-- [PERSONAL EXPERIENCE] -->Das Preissignal ist f\u00fcr die meisten Betriebe wichtiger als die Verbotstermine. Niemand musste K\u00e4lteanlagenbauern sagen, dass sie kein R-22 mehr kaufen sollen, als es in den letzten Jahren war. Der Preis hat das erledigt. Erwarten Sie dasselbe Muster bei R-410A: rechtlich f\u00fcr die Wartung zul\u00e4ssig, aber wirtschaftlich zunehmend unattraktiv im Vergleich zum Umstieg auf ein neues R-32-System. Das Wartungsverbot 2032 setzt nur die endg\u00fcltige Frist f\u00fcr das, was die Wirtschaftlichkeit ohnehin schon entschieden haben wird.<\/p>\n\n\n\n<h2 id=\"faq\" class=\"wp-block-heading\">H\u00e4ufig gestellte Fragen<\/h2>\n\n\n\n<div class=\"faq-section\" itemscope itemtype=\"https:\/\/schema.org\/FAQPage\">\n\n<div class=\"faq-item\" itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"margin-bottom:1.5em;padding:1em 1.2em;border-left:3px solid #f97316;background:#f8fafc;border-radius:0 8px 8px 0;\">\n<h3 itemprop=\"name\" style=\"margin:0 0 0.5em;font-size:1.05em;\">Verbietet der EU-HFC-Phase-Down alle HFKW?<\/h3>\n<div itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\">\n<p itemprop=\"text\" style=\"margin:0;\">Nein. Der Phase-Down reduziert die Gesamtmenge der in der EU in Verkehr gebrachten HFKW bis 2030 auf 5 % des Ausgangswerts von 2015, verbietet HFKW aber nicht vollst\u00e4ndig. HFKW mit niedrigem GWP wie R-32 (GWP 675) bleiben f\u00fcr viele Anwendungen zul\u00e4ssig. Recycelte und r\u00fcckgewonnene HFKW unterliegen gem\u00e4\u00df Artikel 8 der Verordnung (EU) 2024\/573 keiner Mengenbeschr\u00e4nkung. Die Verordnung zielt auf Gase mit hohem GWP und Neuware ab, nicht auf die gesamte HFKW-Familie.<\/p>\n<\/div>\n<\/div>\n\n<div class=\"faq-item\" itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"margin-bottom:1.5em;padding:1em 1.2em;border-left:3px solid #f97316;background:#f8fafc;border-radius:0 8px 8px 0;\">\n<h3 itemprop=\"name\" style=\"margin:0 0 0.5em;font-size:1.05em;\">Wann wird R-32 in der EU verboten?<\/h3>\n<div itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\">\n<p itemprop=\"text\" style=\"margin:0;\">R-32 wird nicht generell verboten. Ab Januar 2027 ist es f\u00fcr neue Split-Klimaanlagen bis 12 kW und Monoblockger\u00e4te gesperrt (GWP-Grenzwert sinkt auf 150). R-32 (GWP 675) \u00fcberschreitet diesen Wert. F\u00fcr gr\u00f6\u00dfere Systeme \u00fcber 12 kW bleibt R-32 jedoch zul\u00e4ssig, ebenso f\u00fcr die Wartung aller bestehenden R-32-Anlagen. Es handelt sich um eine kategoriespezifische Einschr\u00e4nkung, nicht um ein pauschales Verbot.<\/p>\n<\/div>\n<\/div>\n\n<div class=\"faq-item\" itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"margin-bottom:1.5em;padding:1em 1.2em;border-left:3px solid #f97316;background:#f8fafc;border-radius:0 8px 8px 0;\">\n<h3 itemprop=\"name\" style=\"margin:0 0 0.5em;font-size:1.05em;\">Kann ich bestehende R-410A-Anlagen nach dem Phase-Down noch warten?<\/h3>\n<div itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\">\n<p itemprop=\"text\" style=\"margin:0;\">Ja, bis 2032. Ungebrauchtes R-410A (GWP 1.924) liegt unter dem aktuellen Wartungsgrenzwert von 2.500. Ab 2032 sinkt der Grenzwert auf 750, womit ungebrauchtes R-410A ausscheidet. Ab diesem Datum ist nur noch recyceltes oder r\u00fcckgewonnenes R-410A f\u00fcr die Wartung zul\u00e4ssig, ohne zeitliche Begrenzung f\u00fcr r\u00fcckgewonnenes K\u00e4ltemittel gem\u00e4\u00df Artikel 8.<\/p>\n<\/div>\n<\/div>\n\n<div class=\"faq-item\" itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"margin-bottom:1.5em;padding:1em 1.2em;border-left:3px solid #f97316;background:#f8fafc;border-radius:0 8px 8px 0;\">\n<h3 itemprop=\"name\" style=\"margin:0 0 0.5em;font-size:1.05em;\">Ist recyceltes K\u00e4ltemittel im Rahmen des EU-Phase-Down zul\u00e4ssig?<\/h3>\n<div itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\">\n<p itemprop=\"text\" style=\"margin:0;\">Ja. Artikel 8 der Verordnung (EU) 2024\/573 nimmt recycelte und r\u00fcckgewonnene fluorierte Gase vom Quotensystem und von den Inverkehrbringungsverboten aus. R\u00fcckgewonnenes Gas, das dem AHRI-700-Standard entspricht, ist funktional gleichwertig mit Neuware. Da die Versorgung mit Neuware bis 2030 auf 5 % schrumpft, wird der Markt f\u00fcr r\u00fcckgewonnenes K\u00e4ltemittel zum dominierenden Versorgungskanal f\u00fcr die Wartung bestehender HFKW-Anlagen.<\/p>\n<\/div>\n<\/div>\n\n<div class=\"faq-item\" itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"margin-bottom:1.5em;padding:1em 1.2em;border-left:3px solid #f97316;background:#f8fafc;border-radius:0 8px 8px 0;\">\n<h3 itemprop=\"name\" style=\"margin:0 0 0.5em;font-size:1.05em;\">Was ist die Kigali-\u00c4nderung und wie h\u00e4ngt sie mit dem EU-Phase-Down zusammen?<\/h3>\n<div itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\">\n<p itemprop=\"text\" style=\"margin:0;\">Die Kigali-\u00c4nderung (2016) zum Montrealer Protokoll verpflichtet Industriel\u00e4nder, den HFKW-Verbrauch bis 2036 auf 15 % ihres Ausgangswerts zu senken. Die F-Gase-Verordnung der EU geht weiter und strebt 5 % bis 2030 an, sechs Jahre vor dem Kigali-Ziel. Die EU ist weltweit die ambitionierteste Jurisdiktion bei der HFKW-Reduktion und dient als De-facto-Standard, dem andere M\u00e4rkte folgen.<\/p>\n<\/div>\n<\/div>\n\n<div class=\"faq-item\" itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"margin-bottom:1.5em;padding:1em 1.2em;border-left:3px solid #f97316;background:#f8fafc;border-radius:0 8px 8px 0;\">\n<h3 itemprop=\"name\" style=\"margin:0 0 0.5em;font-size:1.05em;\">Wie unterscheidet sich der EU-Zeitplan vom US-amerikanischen AIM Act?<\/h3>\n<div itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\">\n<p itemprop=\"text\" style=\"margin:0;\">Beide folgen dem 85-%-Reduktionsziel der Kigali-\u00c4nderung bis 2036, aber der Weg dorthin unterscheidet sich. Die EU setzt auf ger\u00e4tespezifische GWP-Verbote (Anhang IV) plus Quotenk\u00fcrzungen. Der US-amerikanische AIM Act st\u00fctzt sich haupts\u00e4chlich auf Produktions- und Verbrauchskontingente, mit sektorspezifischen Regeln, die schrittweise eingef\u00fchrt werden. Die EU-Ger\u00e4teverbote greifen fr\u00fcher und h\u00e4rter, w\u00e4hrend die USA K\u00e4ltemittel mit h\u00f6herem GWP in neuen Ger\u00e4ten l\u00e4nger zulassen.<\/p>\n<\/div>\n<\/div>\n\n<\/div>\n\n\n\n<h2 id=\"fazit\" class=\"wp-block-heading\">Fazit<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Der EU-HFC-Phase-Down komprimiert 35 Jahre Umstellung auf ein Jahrzehnt. Von den ersten Ger\u00e4teverboten 2025 bis zur R-410A-Wartungsfrist 2032 bringt jedes Jahr eine st\u00e4rkere Verknappung. Die Quote sinkt bis 2030 auf 5 %. Die Preise werden der Angebotskurve nach oben folgen. Recyceltes Gas wird sich vom Nischenprodukt zum Hauptversorgungskanal wandeln.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ihre Ma\u00dfnahmenliste:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Jetzt:<\/strong> Alle Neuinstallationen f\u00fcr GWP unter 150 auslegen (2027-konform), nicht nur unter 750.<\/li>\n\n\n\n<li><strong>Vor 2027:<\/strong> R-290-Ger\u00e4tealternativen f\u00fcr Systeme unter 12 kW evaluieren.<\/li>\n\n\n\n<li><strong>Vor 2030:<\/strong> Lieferbeziehung f\u00fcr r\u00fcckgewonnenes R-410A zur Wartung bestehender Anlagen aufbauen.<\/li>\n\n\n\n<li><strong>Vor 2032:<\/strong> Austauschplan f\u00fcr den bestehenden R-410A-Anlagenbestand erstellen.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Jede Anlage, die Sie heute installieren, wird unter Vorschriften betrieben, die jedes Jahr strenger werden. Planen Sie f\u00fcr die n\u00e4chste Frist, nicht f\u00fcr die aktuelle. Brauchen Sie Unterst\u00fctzung bei der <a href=\"https:\/\/refrigerationstore.eu\/de\/gas\/kaeltemitteltyp-ihrer-klimaanlage-finden-vollstaendiger-leitfaden-2026\/\">Auswahl des richtigen K\u00e4ltemittels<\/a> f\u00fcr Ihr n\u00e4chstes Projekt? Beginnen Sie mit der Ger\u00e4tekategorie und arbeiten Sie r\u00fcckw\u00e4rts vom GWP-Grenzwert, der zum geplanten Installationsdatum gilt.<\/p>\n\n\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@graph\": [\n    {\n      \"@type\": \"BlogPosting\",\n      \"@id\": \"https:\/\/refrigerationstore.eu\/de\/gas\/eu-hfc-phase-down-zeitplan-2025-2036\/#article\",\n      \"headline\": \"EU-HFC-Phase-Down-Zeitplan 2025\u20132036: Alle Fristen erkl\u00e4rt\",\n      \"description\": \"Die EU-HFC-Quote sank 2025 um 48 %. Dieser Zeitplan erkl\u00e4rt alle Verbote, Wartungsbeschr\u00e4nkungen und Quoten-Meilensteine von 2025 bis 2036.\",\n      \"inLanguage\": \"de\",\n      \"datePublished\": \"2026-05-20\",\n      \"dateModified\": \"2026-05-20\",\n      \"author\": {\n        \"@type\": \"Organization\",\n        \"name\": \"Refrigeration Store\",\n        \"url\": \"https:\/\/refrigerationstore.eu\"\n      },\n      \"publisher\": {\n        \"@type\": \"Organization\",\n        \"name\": \"Refrigeration Store\",\n        \"url\": \"https:\/\/refrigerationstore.eu\"\n      },\n      \"mainEntityOfPage\": {\n        \"@type\": \"WebPage\",\n        \"@id\": \"https:\/\/refrigerationstore.eu\/de\/gas\/eu-hfc-phase-down-zeitplan-2025-2036\/\"\n      },\n      \"translationOfWork\": {\n        \"@type\": \"BlogPosting\",\n        \"inLanguage\": \"en\",\n        \"url\": \"https:\/\/refrigerationstore.eu\/gas\/eu-hfc-phase-down-timeline-2025-2036\/\"\n      },\n      \"image\": \"https:\/\/images.pexels.com\/photos\/27134985\/pexels-photo-27134985.jpeg\",\n      \"about\": {\n        \"@type\": \"Thing\",\n        \"name\": \"EU-HFC-Phase-Down-Verordnung Zeitplan\"\n      },\n      \"keywords\": \"EU HFC Phase-Down Zeitplan, EU F-Gase-Verordnung 2024\/573 Fristen, HFC-Quotenabbau 2025 2030, R-410A Wartungsverbot 2032, Kigali-\u00c4nderung EU, EU K\u00e4ltemittel Verbotstermine, F-Gas-Verordnung Termine\"\n    },\n    {\n      \"@type\": \"FAQPage\",\n      \"@id\": \"https:\/\/refrigerationstore.eu\/de\/gas\/eu-hfc-phase-down-zeitplan-2025-2036\/#faq\",\n      \"mainEntity\": [\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Verbietet der EU-HFC-Phase-Down alle HFKW?\",\n          \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Nein. Der Phase-Down reduziert die Gesamtmenge der in der EU in Verkehr gebrachten HFKW bis 2030 auf 5 % des Ausgangswerts von 2015, verbietet HFKW aber nicht vollst\u00e4ndig. HFKW mit niedrigem GWP wie R-32 (GWP 675) bleiben f\u00fcr viele Anwendungen zul\u00e4ssig. Recycelte und r\u00fcckgewonnene HFKW unterliegen gem\u00e4\u00df Artikel 8 der Verordnung (EU) 2024\/573 keiner Mengenbeschr\u00e4nkung.\"}\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Wann wird R-32 in der EU verboten?\",\n          \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"R-32 wird nicht generell verboten. Ab Januar 2027 ist es f\u00fcr neue Split-Klimaanlagen bis 12 kW und Monoblockger\u00e4te gesperrt (GWP-Grenzwert sinkt auf 150). R-32 (GWP 675) \u00fcberschreitet diesen Wert. F\u00fcr gr\u00f6\u00dfere Systeme \u00fcber 12 kW bleibt R-32 jedoch zul\u00e4ssig, ebenso f\u00fcr die Wartung aller bestehenden R-32-Anlagen.\"}\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Kann ich bestehende R-410A-Anlagen nach dem Phase-Down noch warten?\",\n          \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Ja, bis 2032. Ungebrauchtes R-410A (GWP 1.924) liegt unter dem aktuellen Wartungsgrenzwert von 2.500. Ab 2032 sinkt der Grenzwert auf 750, womit ungebrauchtes R-410A ausscheidet. Ab diesem Datum ist nur noch recyceltes oder r\u00fcckgewonnenes R-410A f\u00fcr die Wartung zul\u00e4ssig.\"}\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Ist recyceltes K\u00e4ltemittel im Rahmen des EU-Phase-Down zul\u00e4ssig?\",\n          \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Ja. Artikel 8 der Verordnung (EU) 2024\/573 nimmt recycelte und r\u00fcckgewonnene fluorierte Gase vom Quotensystem und von den Inverkehrbringungsverboten aus. R\u00fcckgewonnenes Gas, das dem AHRI-700-Standard entspricht, ist funktional gleichwertig mit Neuware.\"}\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Was ist die Kigali-\u00c4nderung und wie h\u00e4ngt sie mit dem EU-Phase-Down zusammen?\",\n          \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Die Kigali-\u00c4nderung (2016) zum Montrealer Protokoll verpflichtet Industriel\u00e4nder, den HFKW-Verbrauch bis 2036 auf 15 % ihres Ausgangswerts zu senken. Die F-Gase-Verordnung der EU geht weiter und strebt 5 % bis 2030 an, sechs Jahre vor dem Kigali-Ziel.\"}\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Wie unterscheidet sich der EU-Zeitplan vom US-amerikanischen AIM Act?\",\n          \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Beide folgen dem 85-%-Reduktionsziel der Kigali-\u00c4nderung bis 2036, aber der Weg dorthin unterscheidet sich. Die EU setzt auf ger\u00e4tespezifische GWP-Verbote plus Quotenk\u00fcrzungen. Der US-amerikanische AIM Act st\u00fctzt sich haupts\u00e4chlich auf Produktions- und Verbrauchskontingente, mit sektorspezifischen Regeln, die schrittweise eingef\u00fchrt werden.\"}\n        }\n      ]\n    },\n    {\n      \"@type\": \"BreadcrumbList\",\n      \"@id\": \"https:\/\/refrigerationstore.eu\/de\/gas\/eu-hfc-phase-down-zeitplan-2025-2036\/#breadcrumb\",\n      \"itemListElement\": [\n        {\n          \"@type\": \"ListItem\",\n          \"position\": 1,\n          \"name\": \"Startseite\",\n          \"item\": \"https:\/\/refrigerationstore.eu\/de\/\"\n        },\n        {\n          \"@type\": \"ListItem\",\n          \"position\": 2,\n          \"name\": \"Gas\",\n          \"item\": \"https:\/\/refrigerationstore.eu\/de\/gas\/\"\n        },\n        {\n          \"@type\": \"ListItem\",\n          \"position\": 3,\n          \"name\": \"EU-HFC-Phase-Down-Zeitplan 2025\u20132036\",\n          \"item\": \"https:\/\/refrigerationstore.eu\/de\/gas\/eu-hfc-phase-down-zeitplan-2025-2036\/\"\n        }\n      ]\n    }\n  ]\n}\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>Der EU-HFC-Phase-Down ist kein einzelnes Verbotsdatum. Es ist eine Treppe, und jede Stufe wird steiler. Die auf dem EU-Markt platzierten HFC-Mengen fielen innerhalb eines Jahres um 37 %, nachdem die \u00fcberarbeitete F-Gase-Verordnung in Kraft trat (Europ\u00e4ische Umweltagentur, 2025). Dieser R\u00fcckgang war erst der Anfang. Verordnung (EU) 2024\/573 ersetzte die urspr\u00fcnglichen Regeln von 2014 durch einen [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":13716,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[47],"tags":[],"class_list":["post-13741","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-gas"],"acf":[],"_links":{"self":[{"href":"https:\/\/refrigerationstore.eu\/de\/wp-json\/wp\/v2\/posts\/13741","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/refrigerationstore.eu\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/refrigerationstore.eu\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/refrigerationstore.eu\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/refrigerationstore.eu\/de\/wp-json\/wp\/v2\/comments?post=13741"}],"version-history":[{"count":4,"href":"https:\/\/refrigerationstore.eu\/de\/wp-json\/wp\/v2\/posts\/13741\/revisions"}],"predecessor-version":[{"id":14735,"href":"https:\/\/refrigerationstore.eu\/de\/wp-json\/wp\/v2\/posts\/13741\/revisions\/14735"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/refrigerationstore.eu\/de\/wp-json\/wp\/v2\/media\/13716"}],"wp:attachment":[{"href":"https:\/\/refrigerationstore.eu\/de\/wp-json\/wp\/v2\/media?parent=13741"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/refrigerationstore.eu\/de\/wp-json\/wp\/v2\/categories?post=13741"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/refrigerationstore.eu\/de\/wp-json\/wp\/v2\/tags?post=13741"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}